TO TEST VALVE PRESSURES:
The pressure taps are located on the front side of the valve (see Figure 35).
1. Follow steps 1-4 in
r
emoVIng
V
alVe
c
oVer
- m
aIntenance
a
nD
s
erVIce
.
to access the valve
.
2. Turn set screw one (1) turn counter-clockwise to loosen.
3. Place
5
/
16
in (8 mm) I.D. hose over the pressure taps.
4. Check pressures using a manometer.
5. When finished, release pressure, remove hose and tighten set screw.
6. Re-install the valve cover, burner tray, brick panels (refer to
s
econDary
I
nstallatIon
- I
nstallIng
the
b
rIck
p
anels
), log set and ember material (refer to
s
econDary
I
nstallatIon
- l
og
s
et
anD
e
mber
I
nstallatIon
) and the glass door.
Always check for gas leaks with a soap and water solution after completing the required
pressure test.
NEVER USE AN OPEN FLAME FOR LEAK TESTING.
23
Initial Installation
QUALIFIED INSTALLERS ONLY
1
2
3
4
5
I
tem
n
umber
D
escrIptIon
1
Control Knob
(On/Off/Pilot)
2
Gas Flow Adjustment
Knob
3
Pilot Adjustment
Screw
4
Inlet Pressure Test
Point
5
Outlet Pressure Test
Point
Figure 35: Valve Details.
Table 6: Valve Details.