19
18"
(457mm)
18"
(457mm)
Trim flashing
as required.
Figure 29: Vertical Vent Cap Dimensions.
Initial Installation
QUALIFIED INSTALLERS ONLY
D
iRect
V
ent
V
eRticaL
V
ent
t
eRmination
:
For use with E20 Direct Vent Fireplace Insert. The Vertical Vent Cap is termination, rain cap, and a
throat connector, it will ensure a tight seal, top performance, safety and efficiency.
KIT COMPONENTS:
Quantity Description
Quantity Description
1
Vertical Direct Vent Termination Cap
1
4 oz Tube RTV Silicone
6
9
/
16
” Tex Screws
1
4 oz Tube Mill-Pac Sealant
Please ensure that all components are supplied with this kit. If components are missing or have
been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if
components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1. Plan your installation and clearances to combustibles. The E20 may be installed and vented into
any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and
local building codes and has been constructed of non-combustible materials. Also refer to the
I
nItIal
I
nstallatIon
- p
reparIng
y
our
e20 F
or
I
nstallatIon
and
c
learances
to
c
ombustIbles
sections. Refer to
Figure 31 throughout installation.
2. Stretch both the Ø3” (76mm) flex vent and the Ø2” (51mm) flex intake liner to the length needed to
ensure the flex can be easily connected to the vent terminal.
3. Install the flex pipe assembly up through the chimney, ensure that the pipe slides through far enough
to connect onto the Vertical Vent Cap.
Note: For any chimney over 15’ (4.6m), install the E20 15’ 2” & 3” Flex Vent (part #50-1512) and
the E20 2” & 3” Flex Couplers (part #50-1513). Place a bead of sealant on the coupler (Mill-Pac Black
sealant for the Ø3” (76mm) and high temperature silicone for the Ø2” (51mm)) Slide the meeting
ends of the flex over the coupler and fasten each joint in place with three (3) sheet metal screws
through the flex and into the coupler.
4. The Vertical Vent Cap can be installed onto chimneys with flue openings up to 16” (406mm) x 16”
(406mm) and the actual flashing is 18”x18” (refer to Figure 29). If the chimney is smaller the cap
should be trimmed down and folded
over.
5. Apply a bead of Mill-Pac Black sealant to
the top section of the Ø3” (76mm) vent
collar plate. Slide the Ø3” (76mm) flex
vent over the flue collar and secure with
three (3) sheet metal screws evenly
spaced.
Note: If fireplace opening is lower than
19” (483mm), remove the vent collar
plate from the top of the insert (see
I
nItIal
I
nstallatIon
- p
reparIng
y
our
e20 F
or
I
nstallatIon
)
and connect it
securely to the liner as stated in Step 4.
Check for tears in the liner at this point.