Figure 15: Burner Removal.
Figure 14: Unfastening Burner.
Maintenance And Service
Kit Parts List:
1 - Orifice (Natural Gas #44 DMS or Propane #55 DMS)
1 - Conversion label
1 - Installation instruction sheet
Carefully inspect the orifice supplied with this conversion kit. If it has been damaged or is missing,
contact your dealer, distributor or courier company to have them replaced before starting this installation.
Conversion Kit Installation:
1. Shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be
shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow
the valve and unit to cool down to room temperature.
2. Remove the glass door as shown in the
m
aIntenance
anD
s
erVIce
- g
lass
D
oor
r
emoVal
.
3. Carefully remove the log set and ember material if they are installed.
4. Using a T-20 screwdriver, remove the
four (4) screws that hold the burner in
place (pointed out in Figure 14). Slide the
burner to the left (see Figure 15), then up
and out of the firebox.
5. Convert the burner orifice:
a) Remove the main burner orifice with a
½ inch deep socket (see Figure 16).
Figure 16: Orifice Removal.
Figure 17: Orifice Replacement.
b) Put a bead of pipe-thread sealant or approved
Teflon tape on the orifice threads before installing
into the brass elbow.
c) Install the new orifice from the kit into the steel
adapter nut (see Figure 17).
6. Convert the pilot:
a) Using a
7
/
16
” wrench, turn the pilot head a ¼
turn counter-clockwise (shown in Figure 18).
b) Push the slider, with your finger or flat head
screwdriver, to the left if it is to be set for natural
gas or to the right for propane, red on the slider will
be visible (see Figure 19).
c) Turn the pilot head a ¼ turn clockwise; back to
its original position.