Initial Installation
QUALIFIED INSTALLERS ONLY
a
iR
R
estRictoR
:
When installing the Berkeley with 10ft (3.05m) or more of vertical venting it may be necessary to restrict the
fresh air supply in the firebox to control the combustion and flame appearance. To install the air restrictor
supplied with the uint the cabinet front and glass door must remove as outlined on page 12 in the
M
aintenance
and
S
ervice
section. The firebox baffle must be removed next by removing the two front screws using a T20
screwdriver (Figure 27). Next, remove the restrictor set screws and install the restrictor at the desired setting
(refer to Figure 28) and tighten the set screws to hold it in place. Refer to Figure 26 on the previous page for the
correct restrictor setting to use in accordance with your installation. Re-install the baffle, glass door, and cabinet
front before operating the Berkeley.
#2
#1
Figure 28: Installation of Air Restrictor
Baffle Screws
Figure 27: Baffle Removal
Set
Screw