Conversion Kit Installation:

1.  Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off 

valve upstream of the unit.  CAUTION: The gas supply must be shut off prior to disconnecting the 

electrical power and before proceeding with the conversion. Allow the valve and unit to cool down 

to room temperature.

2.  Remove the glass door as shown in the 

M

aintenance

 

and

 S

ervice

 - G

laSS

 d

oor

 r

eMoval

3.  Carefully remove the log set.
4.  Remove the burner as shown in the 

M

aintenance

 

and

 S

ervice

 - B

urner

 r

eMoval

5.  Convert the burner orifices:

a) Remove the main burner orifices with a 3/8” socket.
b) Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing 

into the brass elbow. 

c) Install the new orifices from the kit (Left = #56 , Right = #55).

6.  Convert the pilot injector:
 

a) Using a 7/16” wrench, turn the pilot head a ¼ turn counter-clockwise.

 

b) Push the slider, with your finger or flat head screwdriver.

 

  -Natural gas is marked NAT.

 

  -Propane gas is marked LP with an indicating hole between L and P.

 

c) Turn the pilot head a ¼ turn clockwise; back to its original position.

f

ueL

 c

onveRsion

:

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing. 

Warning:  This conversion kit shall be installed by a qualified service agency in accordance 

with the manufacturer’s instructions and all applicable codes and requirements of the 

authority  having  jurisdiction.  If  the  information  in  these  instructions  is  not  followed 

exactly, a fire, explosion or production of carbon monoxide may result causing property 

damage, personal injury or loss of life. The qualified service agency is responsible for 

the  proper  installation  of  this  kit.  The  installation  is  not  proper  or  complete  until  the 

operation  of  the  converted  appliance  is  checked  as  specified  in  the  manufacturer’s 

instructions supplied with the kit.

Kit Parts List for all Berkeley-Nova models:

 

2 - Orifice (NG: #45 & #44) or (LP: 2 x #55 , 1 x #56) 

 

 

 

1 - Installation instruction sheet  

 

 

1 - Conversion label

Carefully  inspect  all  parts  supplied  with  this  conversion  kit.  If  any  parts  have  been  damaged  or  are 

missing, contact your dealer, distributor or courier company to have them replaced before starting this 

installation.

Maintenance And Service

Summary of Contents for Berkeley-Nova

Page 1: ...perty damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html 4001609 W A...

Page 2: ...plumber or gas fitter when installed within the Commonwealth of Massachusetts Other Massachusetts code requirements Flexible connector must not be longer than 36in a shut off valve must be installed o...

Page 3: ...e performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 o...

Page 4: ...Removal 12 Glass Door Removal 12 Burner Removal 13 Fuel Conversion 14 Initial Installation 17 Preparation for Installation 17 Clearance to Combustibles 17 Direct Vent 18 Venting Clearances 18 Approve...

Page 5: ...TERS CAN CGA 2 17 M91 R2014 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 15 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO Berkeley Fireplace Has been certified for use with...

Page 6: ...rkeley Dimensions Rating Label Lighting Instructions Location The rating label and lighting instructions are located on a plate hanging on the back of of the unit 29 5 16 75 5 cm 4 5 8 11 7 cm 30 1 4...

Page 7: ...next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any pho...

Page 8: ...flames to Figure 47 on page 35 The ideal flame will be blue at the base and light orange above The flames should be of medium height If the flames look like this no venturi adjustment is needed If the...

Page 9: ...e Berkeley DO NOT FORCE IT If the unit is going to be serviced turn off the electrical power to the unit as well NOTE When the unit is turned on for the first time it should be turned onto high with t...

Page 10: ...eed of the blower The blower is pushing the heat from the fireplace into the room Gas Control Valve Dull click when turning on or off this is the valve opening and closing Maintenance And Service Rout...

Page 11: ...allation Log Set Installation section If any logs are damaged contact your nearest ENVIRO dealer Replacing the Glass The glass in the fireplace is a high temperature ceramic If the glass is damaged in...

Page 12: ...in Figure 12 To replace the glass door simply reverse the above procedure Warning Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fir...

Page 13: ...3 Place your hands in the air slots in the burners as shown in figure 14 then pull forward and lift up to dis engage the venturi tubes 4 Continue to lift up and rotate the burner approx 45 degrees as...

Page 14: ...en L and P c Turn the pilot head a turn clockwise back to its original position Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before...

Page 15: ...e the screw clockwise until a torque of 9 inch lbs WARNING Do not over tighten the screw It is recommended that you grip the wrench by the short side f Verify that if the conversion is from NG to LPG...

Page 16: ...e until the correct flame is achieved 13 Relight the main burner in both the HI and LO positions to verify proper burner ignition operation and proper flame appearance figure 47 page 35 Confirm the in...

Page 17: ...ng joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the ho...

Page 18: ...and arrangement Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace certain guidelines have been set in Initial Installation Allowa...

Page 19: ...sheild 46DVA WT 4WT Wall thimble 46DVA SC SC Storm collar 46DVA WFS 4CS Fire stop 46DVA WS WS Wall strap support band 46DVA F6 4FA Flashing 0 12 to 7 12 roof pitch 46DVA F7 4FB Flashing 8 12 to 12 12...

Page 20: ...Berkeley A termination guard 50 3266 is required when the termination is within 7 2 13m of grade Figure 24 Minimum Vent Length Approved horizontal termination Approved through wall thimble 24 61 cm Mi...

Page 21: ...at may be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal dis...

Page 22: ...number of elbows is ideal as they tend to disrupt air movement Using 45 elbows is preferable to using 90 elbows Also a shorter vent system will perform better than a longer one The total length of ho...

Page 23: ...e and Service section The firebox baffle must be removed next by removing the two front screws using a T20 screwdriver Figure 27 Next remove the restrictor set screws and install the restrictor at the...

Page 24: ...n The air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal p...

Page 25: ...n the vent termination should be pointing up Run a bead of non hardening mastic around the edges of the vent cap to make a seal with the wall Ensure the proper clearances to combustibles have been mai...

Page 26: ...lashing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that yo...

Page 27: ...ng should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 23 45 elbows x2 Wall strap Plumber s tape connected to wal strap 4 Any occupied areas above the fir...

Page 28: ...the wires are not pinched between the adaptor and the collar and or flue outlet Ensure that the opening of the Drafthood Adaptor is not blocked or obstructed Optional remote control receiver ON OFF Re...

Page 29: ...venting Venting Restrictions The vent lengths below are measured from the floor to the top of the flex venting and cannot run in the horizontal dimension Minimum 10 ft 3 05m Maximum 30 ft 9 14m SPILLA...

Page 30: ...afthood into a non combustible chimney the following optional finishing technique can be used CAUTION Installations where the flue connector or venting connects to or passes through combustible walls...

Page 31: ...s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water sol...

Page 32: ...s For Electrical Installations or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong groundin...

Page 33: ...e unit Then remove the glass door by releasing the top spring latches 2 Next install the ember bed assembly as shown in Figure 41 by holding onto the slots in the ember bed The ember bed must be held...

Page 34: ...Figure 46 Final Top Log 6 Next Install the left and right top logs as shown in Figure 45 Note the locating notches on the bottom side of both logs areas highlighted 7 Install the last log on top on t...

Page 35: ...tion at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports are blocked Maintenance Once a...

Page 36: ...taining bolts Figure 48 using a 1 4 socket and remove the damaged screen while noting the orientation Install the new screen 50 3243 by simply re installing the retaining bolts Re install the cast doo...

Page 37: ...screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas l...

Page 38: ...50 1421 13 Heyco Strain Relief EC 044 14 Domestic Power Cord 115v EC 042 15 Log Set 9 pieces 50 3234 16 Ceramic Burner Assembly 50 3233 17 Front Door Glass w Gasket 16 875 x 21 0625in 50 3235 18 Fron...

Page 39: ...39 Parts List 21 1 24 25 2 9 5 14 13 19 20 23 3 11 12 4 6 10 7 8 18 16 22 17 27 15 26...

Page 40: ...led Antique Chestnut 50 3249 31 Cast Skirt Painted 50 3250 Cast Skirt Enameled Antique Chestnut 50 3251 32 Cast Right Side Painted 50 3252 Cast Right Side Enameled Antique Chestnut 50 3253 33 Cast Lef...

Page 41: ...ar une personne de service certifi ou qualifi Chaud pendant le fonctionnement Ne touchez pas Des br lures graves peuvent en r sulter Gardez les enfants les v tements meubles essence et autres liquides...

Page 42: ...42 Notes...

Page 43: ...ty screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from...

Page 44: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Reviews: