**Alcove (Use double wall pipe) / Alcôve (Utilisant le double connecteur de mur) 

I

Total width / Largeur totale

55” (1397 mm)

Model/Modèle 1200

J

Total height / Hauteur totale

78” (1981 mm)

K

Top of stove to ceiling / Le sommet de poêle au plafond

49” (1245 mm)

L

Sidewall to unit / De la paroi latérale au dispositif
Sidewall to connector / De la paroi latérale au connecteur
Backwall to unit / De la paroi arrière au dispositif
Backwall to connector / De la paroi arrière au connecteur

15” (381 mm)

M

24” (610 mm)

N

12” (305 mm)

O

15” (381 mm)

51” (1295 mm)

Model/Modèle 1700

72” (1829 mm)
44” (1118 mm)

13” (330 mm)
22” (559 mm)

8” (203 mm)

11” (279 mm)

Maximum Depth / Profondeur maximum

P

48” (1220 mm)

48” (1220 mm)

Single wall pipe /

Seul connecteur de mur

**Double wall pipe /

Double connecteur de mur

Top vent out back wall with min. 24” (610mm)

vertical rise; double wall pipe / Donné vent hors 

de la paroi arrière avec le min. 24” (610 mm) 

l'ascension verticale; double connecteur de mur 

A

13” (330 mm)

14” (356 mm)

B

11” (279 mm)

8” (203 mm)

12” (305 mm)

C

9” (229 mm)

6½" (165 mm)

D

22” (559 mm)

22” (559 mm)

23” (584 mm)

E

14” (356 mm)

11” (279 mm)

15” (381 mm)

11” (279 mm)

16” (381 mm)
15” (406 mm)

F

17½” (445 mm)

16½” (419 mm)

10” (254 mm) 

8½" (216 mm)

22” (559 mm) 

17” (432 mm)

15” (381 mm)

7” (178 mm)

6” (152 mm)

22” (559 mm)
10” (254 mm)

14½” (368 mm)

G

† Front of door opening to edge of hearth / 

Le devant d'ouverture de porte au bord de coussin de coeur

USA 16” (406 mm)       CND 18” (450 mm)

USA 6” (152 mm)         CND 8” (200 mm)

H

Sidewall to unit / De la paroi latérale au dispositif

Sidewall to connector / De la paroi latérale au connecteur

Backwall to unit / De la paroi arrière au dispositif

Backwall to connector / De la paroi arrière au connecteur

Adjacent wall to corner of unit / 

De la paroi adjacent au coin de dispositif

Adjacent wall to connector/ 

De la paroi adjacent au connecteur

1200

20” (508 mm)
12” (305 mm)

10" (254 mm)

29” (737 mm)
15” (381 mm)

18½” (470 mm)

1700

1200

1700

1200

1700

1200

1700

Double wall pipe with efficiency 

shield (Flat top model only) / Double 

connecteur de mur avec la protection 

d'efficacité (Le modèle plat seulement

Model / Modèle

Minimum Clearances to Combustible Materials /

Espaces Libres Aux Materiax Combustibles.

13” (330 mm)

13” (330 mm)

13” (330 mm)

13” (330 mm)

13” (330 mm)

13” (330 mm)

13” (330 mm)

22” (559 mm) 

10” (254 mm)

8” (203 mm)

† Side/back of unit to edge of hearth / 

Le latérale/arrière de dispositif au bord de coussin de coeur

H

H

H

G

B

A

D

E

Front /

Mur avant

Hearth / 

Foyer

K

J

Back wall/

Mur arrière

Sid¸e wall / Mur a côté

N

L

M

O

Alcove Back wall /

Mur d’alcôve a l’arrière

Alcove Side wall /  Mur d’alcôve a côté

C

F

C

Front /

Mur avant

Adjacent wall /

Mur adjacent

Adjacent  wall / Mur adjacent

I

Alcove /

Alcôve

Front /

Mur avant

Front /

Mur avant

Certified for use in Canada & USA /

Certifié pour installation au Canada et aux Etats-Unis.

B

A

D

C

Adjacent  w

al

l / Mur adjacent

F

E

CAUTION: An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed 

space, or through a floor, ceiling, wall, or partition, or any combustible construction.

† FLOOR PROTECTION: If a stove is installed on a combustible floor, it must have a pedestal attached and be 

on a NON COMBUSTIBLE hearth pad 

*  ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY.

SINGLE WALL:

IN CANADA:  Any ULC-S629 listed chimney system with the accompanying listed single wall vent connector.

IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed single wall vent connector.

**DOUBLE WALL :

IN CANADA:  Any ULC-S629 listed chimney system with the accompanying listed double wall vent connector.

IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed double wall vent connector.

 DOUBLEWALL IS REQUIRED FOR MOBILE HOME INSTALLATIONS.

† FLOOR PROTECTION / PROTÉGER LE PLANCHER: 

If unit is raised / Si l'appareil est soulevé:

0” - 2” (0mm - 51mm);      1” (25mm) non-combustible material with k value = 0.84 or equivalent / 

                                 1” (25mm) le matériel incombustible avec la valeur de k = 0.84 ou équivalent.

2” - 8” (51mm - 203mm); ½” (13mm) non-combustible material with k value = 0.84 or equivalent / 

½” (13mm) le matériel incombustible avec la valeur de k = 0,84 ou équivalent.

Greater than/Plus grand que 8” (203 mm)      any non-combustible material / 

                                                                n'importe quel type de matériel incombustible. 

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

LISTED SOLID FUEL SPACE HEATER / IDENTIFIE COMME UN FOYER A COMBUSTIBLE SOLIDE

Serial No. / No. De Serié:

Model / Modèle:                     Kodiak 1200 FS             Kodiak 1200 Insert          Kodiak 1700 FS               Kodiak 1700 Insert

Report/Rapport no.                268-S-04-2                     268-S-05-2                     268-S-01-2                       268-S-06-2

Venice 1200 Insert         Boston 1200 Insert        Venice 1700 Insert          Boston 1700 Insert

268-S-05-2                     268-S-06b-2                     268-S-06-2                      268-S-06b-2

Models 1200 and 1700 Freestanding units suitable for use in mobile homes.

Tested to ULC-S627-00, ULC-S628-93, & UL-1482-10.              

US Environmental Protection Agency, certified to comply July 1, 1990, particulate emission standards.

Install and use only in accordance with the manufacturers installation and operating instructions. Contact 

local building or fire officials about restrictions and installation inspection in your area. Use 6” (150 mm) 

diameter minimum 24 MSG black or 25 MSG blued steel connector listed factory-built chimney suitable for 

use with solid fuels or masonry chimney. See local building code and manufacturer’s instructions for 

precautions required for passing a chimney through a combustible wall or ceiling. Do not pass chimney 

connector through a combustible wall or ceiling. Minimum clearances from horizontal connector and ceiling 

18” (455 mm). Do not connect this unit to a chimney flue servicing another appliance.

Modèles 1200 et 1700 items indépendants utilisables dans les maisons mobiles.  

Testé selon ULC-S627-00, ULC-S628-93, & UL-1482-10.                        

États-Unis Environnemental Protection Agence, a certifié pour conformer au Juillet 1, 1990, les normes de particules d'émission.

Ce dispositif doit entre installé et opéré conformément aux instructions d'installation et d'opération du manufacturier contactez le 

service local de l'inspection des bâtiments ou l'officier pompier concernant les restrictions et l'inspection d'installation dans votre 

localité. Utiliser des connecteurs répertoriés 24 MSG noir ou 25 MSG en acier bronzée de 6" (150 mm) minimum, et une 

cheminée de fabrication industrielle, appropriée pour utilisation avec des combustibles solides ou avec une cheminée de 

maçonnerie. Vérifiez les précautions a prendre exigées parle code local et les instructions du manufacturier concernant les 

conditions pour passer la cheminée a travers un mur ou un plafond combustible. Net pas installer le connecteur de la cheminée 

a travers un mur ou un plafond combustible. Espaces libres minimum d'un connecteur horizontal et plafond sont 18" (455 mm) 

ne pas connecter ce dispositif a un conduit de cheminée qui sert déjà un autre dispositif.

DATE OF MANUFACTURE / DATE DE FABRICATION:

J       F       M       A       M       J       J       A       S       O       N       D                             2010       2011       2012      2013       2014

C-12347

MANUFACTURED BY / FABRIQUE PAR: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD, SAANICHTON, BC CANADA

MADE IN CANADA / FABRIQUE AU CANADA

HOT WHILE IN OPERATION. 

DO NOT TOUCH. KEEP CHILDREN, 

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE 

SKIN BURN. READ NAMEPLATE AND INSTRUCTIONS.

CAUTION:

                                                             TRÈS CHAUD QUAND ALLUMÉ.

                                                              NE TOUCHEZ PAS. TENIR LOIS 

LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES. LE CONTACT 

PEUT CAUSER DES BRÛLURES. LISEZ ATTENTIVEMENT 

L’ÉTIQUETTE ET LES INSTRUCTIONS.

MISE EN GARDE:

Operate only with the door and ash pan closed. Only open door to feed fire. For use with solid wood 

fuels only. Do not use any other type of fuel. Do not use grate or elevate-fire build wood fire directly 

on hearth. Do not overfire, do not obstruct combustion air openings. If heater or chimney connector 

glows, you are overfiring. Inspect and clean chimney frequently-under certain conditions of use, 

creosote buildup may occur rapidly. Keep furnishing and other combustibles well away from heater. 

Replace glass only with 5 mm thick ceramic glass. Optional component for FS: fan, electrical rating 

115V, 60 Hz 1 Amp (Part # EFW-261). 

Danger:

 Risk of electrical shock. Disconnect power before servicing unit. Route cord away from 

heater.

Models 1200 and 1700 inserts may be installed as an insert in a masonry fireplace. / On peut encastrer le modèles 1200 et 1700 dans un foyer de maçonnerie.

L'opération du poêle doit se faire avec la porte et le cendrier fermé. N'ouvrir la porte que pour alimenter le feu. N'utilisez que des 

combustibles solides. Ne pas utiliser un autre type de carburant. N'employez pas de grille de foyer ou ne surélevez pas le feu. 

Mettez le bois à brûler directement sur l'âtre. Pour éviter la surchauffeur, ne mettez pas trop de bois. N'obstruez pas les ouvertures 

d'air comburant. Si le poêle ou le connecteur commencent à luire, vous surchauffez le poêle. Inspectez et nettoyez la cheminée 

souvent. Dans certaines conditions, le créosoté peut s'accumuler rapidement. Tenez loin les meubles et d'autres produits 

combustibles. Ne remplacez le verre qu'avec du verre céramique, 5mm épais. Équipement en option pour un FS: ventilateur 

caractéristiques assignées 115V, 60 Hz, 1 Amp (pièce # EFW-261) tenez le câble électrique loin du poêle. 

Danger:

 Le risque de choc électrique. Débrancher le dispositif avant d'entretenir. 

MISE EN GARDE: Un uninsulated tuyau de fumée ne doit pas passer par un grenier, un espace de toit, le placard ou 

l'espace dissimulé similaire, ou par un plancher, un plafond, un mur, ou une cloison, ou une construction combustible. 

† PROTÉGER LE PLANCHER: Si une cuisinière est installée sur un sol combustible, il doit avoir un piédestal attache et 

être sur un coussinet non- combustible.

TOUS “ESPACES LIBRES AUX MATERIAX COMBUSTIBLES” PEUVENT ÊTRE RÉDUITS AVEC PROTÉGEANT

ACCEPTABLE À L’AUTORITÉ LOCALE. 

Seul Connecteur de Mur:

Au Canada: Certifiée  seul connecteur de mur avec toute systèmes de cheminée listée sous ULC-S629.

Aux États-Unis: Certifiée seul connecteur de mur avec toute systèmes de cheminée listée sous UL 103 HT.

**Double Connecteur de Mur:

Au Canada: Certifiée  double connecteur de mur avec toute systèmes de cheminée listée sous ULC-S629.

Aux États-Unis: Certifiée double connecteur de mur avec toute systèmes de cheminée listée sous UL 103 HT. 

DOUBLE CONNECTEUR DE MUR NÉCESSAIRES POUR INSTALLATION DANS LES MAISONS 

MOBILE.

Tested &

Listed By

Model / Modèle  

                                             1200 FPI                   1700 FPI

A  To unshielded side wall / aux mur non protegé 

                                                  10” (254 mm)          10” (254 mm)

B  To an unshielded 8” (203 mm) mantle / aux manteau 8“ non protegé 

                   21” (533 mm)          24” (610 mm)

C  To top facing (protruding ¾” [19 mm]) clearance / aux revêtement supérieur              17½” (445 mm)      19½” (495 mm)
D  To side facing (protruding ¾” [19 mm]) clearance / aux revêtement a côté                    1” (25 mm)               1” (25 mm)
E     † From door opening of unit to edge of floor protection / 
       De ouverture de la porte de l'unité à bord de la protection de plancher                USA 16” (406mm) / CND 18” (450mm)

 F     † From side of unit to edge of floor protection / 
        Du côté de l'unité au bord de la protection de plancher                                        USA 6” (152 mm) / CND 8” (200 mm)

Figure 33: Rating Label Sample

Summary of Contents for 1200-C Insert

Page 1: ...fire officials or the authority having jurisdiction about restrictions and installation inspection requirements in your area This heater meets the U S Environmental Protection Agencies emission limits for wood heaters sold after July 1st 1990 Under specific conditions this heater has been shown to deliver heat at rates ranging from 11 479 to 34 196 BTU per hour for the 1200 and from 9 425 to 31 78...

Page 2: ... Masonry Fireplace Installation 16 Installation Using A Block Off Plate For USA Only 19 Model 1200 C Brick Placement Tube Locations 21 Model 1700 C Brick Placement Tube Locations 22 C Cast Ceramic Baffle Installation 23 Fan Wiring Diagrams 24 Removal of Cast Top 25 Removal of Cast Door 25 Removal of Cast Side Panels 26 Removal of Cast Side Brackets 26 Removal of Surround Panel 27 Removal of Lower ...

Page 3: ... DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE GREASE NAPHTHA OR ENGINE OIL Never let the stove become hot enough to get any part red or glowing red Burning wet unseasoned wood could cause excessive creosote accumulation in the flue pipe When ignited it could cause a chimney fire that could result in a serious house fire Do not use grates irons or any other methods to support or raise t...

Page 4: ...he dial rotation is as follows OFF HIGH LOW 3 If the dial is in any position in the high to low range the fan will automatically turn on once the stove has reached operating temperature roughly 25 mins from a cold start When the unit cools down the fan temperature sensor will shut the fan off automatically The fan can also be turned off manually at any time by rotating the dial to the off position...

Page 5: ...certain the chimney and its lining have not been damaged Building Your Fire Proper operation of your stove will help to ensure safe efficient heating Please take a few moments to review these simple operating procedures IMPORTANT Please be aware when loading your stove that the air tubes in the rear are lower 1 Fuel Selection This stove is designed to burn natural wood only Higher efficiencies and...

Page 6: ...ket seal could be compromised 4 For Maximum Efficiency When the stove is hot load it fully to the top of the door opening and burn at medium low settings When the fuel is mostly consumed leaving a bed of red coals repeat the process Maximum heat for minimum fuel occurs when the stove top temperature is between 250 F 120 C and 550 F 290 C The most likely causes of dirty glass are not enough fuel to...

Page 7: ...burn pieces up to 20 long logs Burn only dry seasoned wood It produces more heat and less soot or creosote Freshly cut wood has about 50 moisture A 10 pound 4 5 Kg log contains 5 pounds 2 3 Kg of water To season firewood split and stack it so that air can get to all parts of the wood Burn beach wood only if its salt content has been washed away in a season of rain and then the wood dried To preven...

Page 8: ...ased amounts of insulation vinyl windows extra caulking in various places and door seals can all keep heat in but may also make a home too airtight An easy way to stop negative pressure in a home is to crack a window in the room containing the stove b Environmental Conditions High trees low lying house location such as in a valley tall buildings or structures surrounding your house and windy condi...

Page 9: ...w air wash cooler air to keep the glass clean Pilot air through Twin pilot injection ports Slider plate used for air flow control Intake air Hole Size ALL DIMENSIONS IN INCHES TOLERANCE General Angles Hole Pos UNLESS OTHERWISE SPECIFIED MATERIAL Sherwood Industries Ltd Part Description Exhaust Smoke 1 2 Ceramic baffle reflects heat down to burn the particles in the smoke Secondary air tubes create...

Page 10: ...x 794 mm Rating Label Location Side of Unit Behind Right Shroud 10 Specifications Air Control The primary air is controlled by the rod located on the right side of the unit To increase your air pull the rod out and to decrease push the rod in All the units have a secondary air that flows through the tubes at the top of the firebox just below the baffles Pull this control all the way out when first...

Page 11: ...ombustible spacers 14 357 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spacers 10 267 mm NOTES 1 Mantel protection must have at least 3 75mm edge clearance on all sides except as provided in Note 4 2 If an adhesive is used to support non combustible material it shall not lose adhesiv...

Page 12: ... combustible spacers 16 408 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spacers 12 305 mm NOTES 1 Mantel protection must have at least 3 75mm edge clearance on all sides except as provided in Note 4 2 If an adhesive is used to support non combustible material it shall not lose adhes...

Page 13: ...cations Dimensions 1200 C Insert Figure 4 1200 C Insert Dimensions 49 1 8 1248mm 35 1 16 891mm 5 127mm 553mm 21 3 4 22 5 16 566mm 20 13 16 528mm 30 13 16 783mm 20 7 8 19 9 16 or 484mm 497mm 19 1 16 529mm 14 355mm ...

Page 14: ...ns Dimensions 1700 C Insert Figure 5 1700 C Insert Dimensions 14 35 1 16 891mm 26 1 4 667mm 5 127mm 49 1 8 1248mm 22 5 16 566mm 20 7 8 470mm 18 1 2 529mm 497mm 19 1 16 484mm or 19 9 16 30 13 16 783mm 528mm 20 13 16 ...

Page 15: ...ctory height of 199 16 497mm and it can be reduced to 191 16 484mm by modifying the unit and the surround panel 1 Remove the thirteen T 20 screws holding the cabinet top in place refer to Figure 8 2 Remove the cabinet top and flip it onto its top 3 Remove the Air Deflector shown in Figure 9 by removing the two 2 T 20 screws 4 Re install the cabinet top onto the unit The screw holes along the top o...

Page 16: ...less steel liner that goes directly to the top of the chimney and is covered with a rain cap The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner The installation must conform to the liner s manufacturer s instructions This fireplace must be installed with a continuous liner of 6 diameter CANADA ONLY extending from the fireplace insert to the top o...

Page 17: ...ert Installation into existing fireplace without hearth f Place the Collar Puller over the two bolts of the Flue Collar and pull it into place see Figure 14 Ensure that the bolts are to the left and right of the hole If they are not the front secondary air tube will need to be removed in order to install or remove the C Cast Ceramic Baffles g Slide the Flue Collar Clamps and washers over the bolts...

Page 18: ...e plate Let the silicon or cement dry 2 To make the installation of the surround panel onto the unit easy have the unit 6 150mm out from the fireplace 3 Push the insert into the fireplace allowing the insulation to form a seal between the panels and the fireplace Tuck any exposed insulation behind the face plate Figure 16 Installation with Surround Sealed 4 Screw or nail the provided metal plate w...

Page 19: ... height where the block off plate will be installed B The width at the back of the firebox at the height where the block off plate will be installed C Then depth of the block off needed the distance between A and B D The distance of the center of the flue to the front of the fireplace opening Refer to Step 3 NOTE In general masonry fireplaces have square fireboxes while zero clearance metal firepl...

Page 20: ... 12 305mm past the block off plate Zero Clearance Notes The fireplace must not be altered except for the exceptions below The permanent metal warning label provided must be attached to the back of the fireplace stating that the fireplace may have been altered to accommodate the insert and must be returned to original condition for use as a conventional fireplace The following modification of facto...

Page 21: ...t until the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Partial Brick Full Size Brick Tube A Tube E Tube D Full Size Brick Figure 21 Brick Placement for 1200 C shown with Secondary Air Channel and Tubes 1 Place the three 3 full size bricks along each side of the firebox an...

Page 22: ... the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Full Size Brick Partial Brick Tube A Tube C Tube B Full Size Brick Full Size Brick Figure 22 Brick Placement for 1700 C shown with Secondary Air Channel and Tubes 1 Place the four 4 full size bricks along each side of the fi...

Page 23: ...Baffle 3 Slide the left C Cast Ceramic Baffle in over the secondary air tubes The tab must be on the bottom and pointing towards the center and the smooth side is to face down 4 Pull the baffles together in the middle so the right tab rests on top of the left tab Ensure the baffles are flush with the back and both sides of the firebox Note If the bolts on the flue collar are not to the left and ri...

Page 24: ...AFETY STANDARDS FOR ELECTRICAL INSTALLATIONS or THE NATIONAL ELECTRICAL CODE ANSI NFPA 70 in the USA CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing DO NOT oil the fan bearings DO NOT cut or remove the grounding prong from the plug DO NOT route the power cord beneath the heater W...

Page 25: ...y ensure that slots in the brackets are fully seated on the bolts Figure 25 Removal of Cast Top 25 CAUTION ENSURE POWER CORD IS UNPLUGGED AND UNIT IS COLD BEFORE ATTEMPTING ANY DISASSEMBLY 1 Fully open the door 2 With the help of another person lift the door straight up off the hinge pins Removal Of Door Removal Of Cast Top Figure 26 Removal of Door ...

Page 26: ...ut to remove it Repeat steps 1 and 2 for other side Figure 28 Cast Side Bracket Bolts Figure 27 Cast Side Panel Screws Removal Of The Cast Side Panels 1 Loosen but do not remove the three 1 4 screws on the side casting using a 3 8 wrench 2 Lift the side casting up and out Repeat steps 1 and 2 for other side Removal Of Side Brackets ...

Page 27: ...an control dial by gently pulling straight up 2 Remove the two screws on the left side with a 5 16 socket and then do the same for the three screws on the right Be sure to support the panel before removing the last screws 3 With the help of another person carefully lift the surround panel up ...

Page 28: ...t Casting Removal 1 Use a 3 8 wrench to loosen the two 1 4 bolts 2 The cast trim bracket can now be lifted off the keyslots Power cord not shown 3 Repeat for the other side Note the slider knob must be unscrewed from the slider rod for the other side Figure 31 Lower Side Cast Removal 28 Removal Of Lower Side Cast ...

Page 29: ...28 Right side only 2 Use a 3 8 socket to loosen the two 1 4 bolts and slide the latch slightly back Retighten the bolts and latch the handle The handle should provide a bit of resistance and close firmly 29 Figure 34 Latch Adjustment 1 Follow the disassembly steps from Figures 25 28 Left side only 2 Pull off the fan control dial by lifting up 3 Unplug the wire connections A light wiggle will help ...

Page 30: ...ector through a combustible wall or ceiling Minimum clearances from horizontal connector and ceiling 18 455 mm Do not connect this unit to a chimney flue servicing another appliance Modèles 1200 et 1700 items indépendants utilisables dans les maisons mobiles Testé selon ULC S627 00 ULC S628 93 UL 1482 10 États Unis Environnemental Protection Agence a certifié pour conformer au Juillet 1 1990 les n...

Page 31: ...4 16 1200 1700 Right Shield Assembly 50 1145 17 1200 C Cast Ceramic Baffle 1 Piece 50 1146 18 1700 C Cast Ceramic Baffle 1 Piece 50 1147 19 1200 1700 Insert Flue Collar Assembly 50 1148 20 1200 1700 Ceramic Flue Gasket 50 1413 21 Kodiak Venice FPI Angled Flue Collar 50 1565 22 1200 1700 Replacement Fan w Mount 50 2390 23 Woodstove Poker 50 1816 24 Boston Steel Surround Panel 50 2415 25 Boston Cast...

Page 32: ...32 Parts Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 ...

Page 33: ...al purchaser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set herein and no claim shall be made against the manufacturer on any oral warranty or representation All claims under this Limited Warranty must be made in writing by your dealer 2 Any stove or part thereo...

Page 34: ...nty will cover glass thermal breakage only and will not cover misuse of the stove glass including but not limited to a Glass that is struck has surface contaminates or has had harsh or abrasive cleaners used on it b If the door is slammed or is closed while wood in the firebox is protruding out the stove opening thus striking the glass 9 This warranty does not cover products made or provided by ot...

Page 35: ...resentations 24 Sherwood Industries Ltd will not cover the cost of the removal or re installation of the stove hearth facing mantels venting or other components 25 Labour to replace or repair items under this Limited Warranty will be covered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 26 Sherwood Industrie...

Page 36: ..._______________ _________________________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE ______________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADDRE...

Reviews: