STACK 710
7 Maintenance
ENVEA
UK Ltd
(PC-000878-MA Issue 7, December 2021)
61
Undo the eight screws (A). Pull the cover back about 50 mm (2”). Reach in and
disconnect the touch panel connector (B) by pulling it towards the rear. Remove
the cover completely.
7.5.2
Replacing the cover
First, check that the sealing cord (D) is clean, evenly pressed down into its
channel, continuous and undamaged. Replace the cover, ensuring that the touch
panel cable is extended towards the front. Stop when the cover is nearly in place
and plug the touch panel connector onto the pins on the display board (C). Push
the cover fully into place and tighten the six screws firmly and evenly. Finally,
check that the sealing cord is evenly compressed round the case. The gap between
the metal parts should be 0.5 mm.
7.6
Configuration Record Sheet
Please complete the Configuration Record Sheet.
General Information
Instrument Serial
Number
Date of Purchase
Technical Information
Pathlength
Service History
Date
Action