Operating temperature:
-20 to 55 °C / -4 to 131 °F
(-40 °C / -40 °F with optional heater)
Maximum Flue Gas
temperature:
600 °C / 1112 °F
Maximum Flange Temp:
200 °C / 392 °F
Environmental rating:
IP65 / NEMA4X
Compliance
Measurement standards:
Meets or exceeds US EPA requirements for 40CFR60
Sections 13, 17 and App. B PS1 Meets or exceeds ASTM
Standard D6216 - 07
Safety:
Conforms to EN-61010-2
EMC:
Conforms to E-50 081 & EN-50 082
Outputs
Modbus Interface:
RS485.
Opacity, Optical Density, Dust Density,
and Status information available
Analogue Outputs:
Isolated 4-20mA current output.
Configurable as Opacity, Optical Density, Dust Density
Relay Outputs:
System OK, Calibration, Alarm
Power Supply
DC Power:
18 to 30 V DC
0.25A (without heater)
2.25A (with heater)
Weight
Transceiver:
7kg (15.5lb)
Retro-reflector:
3.2kg (7lb)