8.2.5 Sensor
Selection:
The evaluation unit verifies the availability of
SolidFlow 2.0 / Paddy /
registered sensors on the selected type,
PicoFlow / MaxxFlow HTC / calculates the measurement values on this
DensFlow / SpeedFlow 2.0 / basis and signals if necessary corresponding
SlideControl 2.0 / ProSens / errors.
M-Sens 2 / M-Sens 3 /
Incorrect sensor selection leads to a refusal
M-Sens WR
to communicate.
8.3. Display
8.3.1 Sensor info
Selection:
ON / OFF
ON:
show info key on display
OFF:
hide info key
8.3.2 Process indicator
Selection:
ON / OFF
ON:
Process indicators will be shown on
display and via double blink on the DIN Rail.
OFF:
Process indicators will not be shown.
8.3.3 Totalisator
Selection:
ON / OFF
ON:
Totalisator will be shown on display.
OFF:
Totalisator will be hide.
8.3.4 Backlight
Input:
0 … 99 min
Lighting of the Display in minutes
0 = permanent lighting
99 = time selection for lighting
8.3.5 Contrast
Input:
0 … 100 %
In the case of display exchange, the contrast
can be changed via the PC software, if
necessary.
8.4
Address
Input:
1… 255
ModBus address of evaluation unit, if
operated on a PLC or PC as a slave.
8.5
Baud rate
Selection:
Communication speed of the evaluation unit
4800/9600/19200/
when this is operated as a ModBus slave on
38400 baud
a PLC or a PC.
8.6
Password
Input:
0… 9999
0000 = No password
XXXX = Four-digit password, which is
queried when the menu is called up on the
display. Automatic lock five minutes after the