![envea PicoFlow Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/envea/picoflow/picoflow_operating-instructions-manual_2415514018.webp)
18
Save changes?
Y
N
Sensor Status
Temp Raw value
Stat
S1 --- 0.000123 OK
S2 --- 0.000213 OK
S3 --- 0.000321 OK
Average 0.000219
3728.25 kg
With the key [I] you can choose between different
information windows. The first window shows the raw values,
temperature and the status of the sensor.
The second window displays the error memory.
Recent error codes always come first. If an error code is
repeated, it will appear first, but will not be listed multiple
times.
If any data has been changed, the change will only be taken
into account when you exit the complete menu structure and
answer [ Yes ] when asked if you wish to save the changes.
For reasons of simplicity, a further display menu screen has been dispensed with.
The display screens are directly derived from the menu structure in section 6.5.
Protection against unauthorised use:
If a password has been entered in menu
8. System
in
8.6 Password
, which is different to the “0000”
default setting, you will be asked to enter a password when attempting to access the menus.
After the password has been successfully entered, the menus will be unlocked for approx. 5 minutes (from
the last menu entry).