background image

12

12

EN

Manual GS-500_EN_2014-01

2.   Open a web browser and type in http://gs-configurator.entrya.eu/
3.   Enter the received login details and press 

Login

 button.

4.  After the system configuration is complete, use one of the following methods to end the configuration process:
  • Wait for the session timeout and the system to reply with an SMS text message confirming the end of the session.
  • Shut down the connection with the configuration server at any time by sending an SMS text message.

Shut down the 

connection with 

configuration server

SMS

SMS text message content:

ssss_STOP

Value: 

ssss

 – 4-digit new SMS password.

Example

1111_STOP

ATTENTION: 

  Output control is disabled during the remote configuration process.

6. SYSTEM LANGUAGE

The system comes equipped with a multiple languages for communication with the administrator by SMS text messages. The default 

system language depends on the firmware, which is based on the customer’s location. 

List of currently available system languages:

• 

English

• 

French

• 

Dutch

• 

German

• 

Italian

• 

Spanish

Set system language

SMS

SMS text message content:

LN

Value: 

LN

 – language index; range – [EN – English, FR – French, NL – Dutch, DE - German,  

IT – Italian, SP – Spanish].

Example: 

FR

Config 

Tool

This operation may be carried out from the PC using the 

GS-Configurator

 software.

WEB

BROWSER

This operation may be remotely carried out from the PC using the web browser.

NOTE: 

  To change the language by SMS text message once the system has already been configured, you need to reset the device to 

the default configuration.  For more details on how to do this, please refer to

 19.2. Restoring Default Parameters.   

Summary of Contents for GS-500

Page 1: ...GSM REMOTE CONTROL GS 500 USER MANUAL...

Page 2: ...by an EN 60950 1 approved supply When connecting the power supply to the system switching the polarity terminal places does not have any affect External power supply can be connected to AC mains only...

Page 3: ...ATABASE 17 10 1 User Validity and Access Restriction 20 11 OUTPUTS 23 11 1 Output Names 23 11 2 Output Control by Free of Charge Phone Call 24 11 3 Output Control by SMS Text Message 25 11 4 Output Co...

Page 4: ...4 4 EN Manual GS 500_EN_2014 01...

Page 5: ...specified The warranty is void if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environments or force majeure factors Dear Customer Thank you...

Page 6: ...ty limitation in accordance with a set deadline date time or number of rings to the system Output control restriction for users in accordance with the specified weekdays and time Event log of 1000 eve...

Page 7: ...tton for setting user telephone numbers GSM g Green light emitting diode indicating GSM signal strength GSM r Red light emitting diode indicating SIM card status STATUS Bue light emitting diode indica...

Page 8: ...g OUT1 OUT2 simultaneous Steady ON Excellent Flashing every 1 sec Programmation telephone numbers activating OUT1 Flashing 2 times per sec Programmation telephone numbers activating OUT2 2 3 Wiring Di...

Page 9: ...e the default SMS password see 7 SMS PASSWORD for more details 9 Set the phone number for Admin 1 see 8 ADMINISTRATOR PHONE NUMBERS for more details 10 Set system date and time see 9 DATE AND TIME for...

Page 10: ...eter and value For some parameters the value does not apply e g STATUS The variables are indicated in lower case letters while a valid parameter value range is indicated in brackets 5 2 Programming bu...

Page 11: ...on may be remotely carried out from the PC using the web browser Establish remote connection for custom session duration SMS SMS text message content ssss_CONNECT TIMEOUT ses d Value ssss 4 digit new...

Page 12: ...ocess 6 SYSTEM LANGUAGE The system comes equipped with a multiple languages for communication with the administrator by SMS text messages The default system language depends on the firmware which is b...

Page 13: ...he alarm SMS text messages from the system s inputs see 14 1 Input Names and Alarm Notification GS 500 allows to assign output C1 output C2 or both outputs simultaneous control to a certain administra...

Page 14: ...5 Example 1111_NR2 DEL Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web bro...

Page 15: ...m start up and periodically by default every 30 days Via GSM network Once enabled the system automatically sends a date time request to the GSM operator This method is the most accurate synchronizatio...

Page 16: ...r NOTE When setting up automatic date and time synchronization feature remotely you may wish to restart the system when done For more details please refer to 18 REMOTE SYSTEM RESTART NOTE The 0 value...

Page 17: ...The blue STATUS LED light starts flashing every 2 sec for 10 minutes or until the USR PROG button is pressed again briefly 3 Dial the system s phone number before the 10 minute period expires using t...

Page 18: ...Value ssss 4 digit SMS password ttteeellnnuumm up to 15 digits user phone number o output number range 1 output C1 2 output C2 3 both outputs user name up to 16 characters user name Example 1111_OUTPU...

Page 19: ...d of deleting all users from the database please disable the user database using one of the following configuration methods Disable user database SMS SMS text message content ssss_DBM_OFF Value ssss 4...

Page 20: ...111_NSCHED_John_5 ON Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web brows...

Page 21: ...teeellnnuumm_ or ssss_EXPIRYTIME_user name_ Value ssss 4 digit SMS password ttteeellnnuumm up to 15 digits user phone number user name up to 16 characters user name Example 1111_EXPIRYTIME_44170911111...

Page 22: ...ig Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Remove ring counter fr...

Page 23: ...11 1 Output Names The output s has a name that can be customized Typically the name specifies a device type connected to a determined output for example Gate The name can be used instead of output nu...

Page 24: ...dministrators phone number For more details please refer to 11 4 Output Control Confirmation by Call Back Set output pulse duration SMS SMS text message content ssss_TIMER1 pl Value ssss 4 digit SMS p...

Page 25: ...the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Turn OFF output for time period SMS SMS text message content ssss_Co OFF hr mn sc...

Page 26: ...11_C2 OFF Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser NOTE Out...

Page 27: ...operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser Disable output control confirmation...

Page 28: ...etails on how to set up the schedulers please refer to 12 SCHEDULERS Assign scheduler SMS SMS text message content ssss_OSHEDo_c ON Value ssss 4 digit SMS password o output number range 1 output C1 2...

Page 29: ...11_SCHED4_AL OFF Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser E...

Page 30: ...R This operation may be remotely carried out from the PC using the web browser Select Every Day SMS SMS text message content ssss_SCHEDc_AL ON Value ssss 4 digit SMS password c scheduler number range...

Page 31: ...mwillsendthenotificationbySMStextmessagetotheadministrator phone number To clear the event log and or disable enable the notification regarding the full event log please refer to the following configu...

Page 32: ...refer to the following configuration methods Enable FIFO type log Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remote...

Page 33: ...ay be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be remotely carried out from the PC using the web browser The system allows to view the current input st...

Page 34: ...MS SMS text message content ssss_SMSALL ON Value ssss 4 digit SMS password Example 1111_SMSALL ON Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWS...

Page 35: ...re WEB BROWSER This operation may be remotely carried out from the PC using the web browser Enable input SMS SMS text message content ssss_Zn ON Value ssss 4 digit SMS password n input number range 1...

Page 36: ...e administrator phone number periodically The recommende period is once a day at 11 00 frequency 1 day time 11 The minimum period is every 1 hour frequency 0 days time 1 Typically this feature is used...

Page 37: ...r phone number provided by the GSM operator must be set manually Set SMSC phone number SMS SMS text message content ssss_SMS_ ttteeellnnuumm Value ssss 4 digit SMS password ttteeellnnuumm up to 15 dig...

Page 38: ...ntent ssss_SETGPRS Value ssss 4 digit SMS password Example 1111_SETGPRS Config Tool This operation may be carried out from the PC using the GS Configurator software WEB BROWSER This operation may be r...

Page 39: ...Unnecessary space character might have been typed in SMS text message For product warranty repair service please contact your local retail store where this product was purchased If your problem could...

Page 40: ...anced written authori zation by Entrya Technologies BVBA Entrya Technologies BVBA reserves the right to update or modify this document and or related products without a warning Hereby Entrya Technolog...

Reviews: