11.4 Second level menu - BA (Basic Adjustment)
Display
Description
Selections
available
TC - Setting of automatic closing time [s]
It is set with different intervals of sensitivity.
•
from 0” to 59” with intervals of 1 second
•
from 1’ to 2’ with intervals of 10 seconds
1’00”
RP - Adjustment of partial opening measurement [%]
Adjusts the percentage of operation in relation to the total opening
of the automation.
Partial opening is performed on gate wing 1.
10 - Minimum
99 - Maximum
50
TP - Setting of automatic closing time after partial opening [s]
It is set with different intervals of sensitivity.
•
from 0” to 59” with intervals of 1 second
•
from 1’ to 2’ with intervals of 10 seconds.
30
VA - Opening speed [V]
NB:
MAX = 20 for:
LUXO5BH
ARC1BH
DOR1BH
CUBIC6H-30H
BOX3SH
DOKE
POWER 50H
See paragraph 11.2.1
Display
Description
Selections
available
PP - Setting step-by-step sequence from command 30-5
ON - Opening-Stop-Closing-Stop-Opening
OF - Opening-Stop-Closing-Opening
S5 - Duration of STOP in step-by-step sequence from command
30-5
ON - Permanent
OF - Temporary
VS - Checking the mechanical end stops
When enabled (ON), every time the power supply is connected the automation
automatically checks the mechanical stops and/or stop limit switches during
opening and closing at the speed set with the adjustment
→
.
During the learning operation, the display shows the message
and the closing
operation involves one gate wing at a time (
).
CM - Motor circuit with automation idle
CL - with the automation idle, the motor is kept in short-circuit
OP - with the automation idle, the motor is kept open
In the case of a reversible automation, set
→
to allow the
motor to rotate freely.
BC
BA - B
a
si
c adj
u
s
tmen
t
See paragraph 11.2.1