17
IP2246EN
8.1 Inserting plug-in boards (AUX)
To access the slots for plug-in boards (AUX):
•
If you want to insert just one board, cut the control panel cover and remove it as
shown in the figure.
•
If both slots are needed, remove the cover completely.
8.2 SOFA1-SOFA2 or GOPAVRS self-controlled safety edge
Command
Function
Description
GOPAV
SOFA1-SOFA2
SAFETY TEST
Insert the SOFA1-SOFA2 or GOPAVRS device in the slot
for plug-in boards AUX1 or AUX2.
If the test fails, an alarm message appears on the
display.
1
6
NC
SAFETY STOP
When selecting
→
→
, connect the output
contact of the safety device to terminals 1-6 on the con-
trol panel (in series with the photocell output contact,
if installed).
1
8
NC
CLOSING SAFE-
TY DEVICE
When selecting
→
→
, connect the output
contact of the safety device to terminals 1-8 on the con-
trol panel (in series with the photocell output contact,
if installed).
1
6
8
NC
CLOSING/
OPENING
SAFETY DEVICE
When selecting
→
→
, connect the output
contact of the safety device to terminals 1-6-8 on the
control panel (in series with the photocell output con-
tact, if installed).
If
→
,
and
cannot be
or
.
36 35 34 33 32 31
+
-
LP
-
+
LK
30 5 20
0 1 6
0 1 8
30 2
3 4
9 13
AUX1
AUX2