6.  EXAMPLE OF APPLICATION WITH COME SELECTOR

The automation opens with commands 1-3A, 1-3B of the RADARs (or opens partially with the 27-3A, 27-3B 
commands), and automatically closes according to the operation chosen on the selector. Makes the safety on 
the passage opening with the CELPR photocells.

24 V

+

-

Internal

radar

External

radar

1

24 V

+

-

2

24 V

+

-

Left

opening safety

Right

opening safety

3

24 V

+

-

4

24 V

+

-

Door lights

24 V

Stop

Power reset

Key open

Closing

Key close

Battery status

24 V

Pass signal

24 V

NO

NC

C

General purpose

Internal closing safety

External closing

safety

0

13

A

27

0

13

B

27

4
1

1

KO

KC

PTS

0

1
16

A

6B

41

1

92

9

BST

1

G1

G2

0

1
18

A

8B

41

1

LM

LC

A

B

C

D

ON

OFF

12

3

4

J4

J5

5

24 V

+

-

6

J1

J2

J3

0

11

2

3A

3B

9

27

28

29

ON

OFF

12

3

4

5

6

SA

POWER ALARM

IN

VA

R1

VC

TC

RP

OPEN

0

16

8

41

R1

SR

R2

P1

SP

P2

0

12

1

22

CELPR

P1

R1

MD1

COME

1

4

5

6

3

2

WARNING: do not use the terminal board of the control panel; make the connections shown in the 
figure.

Summary of Contents for Ditec MP1

Page 1: ...1 23 Installation manual for accessories connection module for EL20 control panel EN DITEC S p A Via Mons Banfi 3 21042 Caronno Pertusella VA ITALY Tel 39 02 963911 Fax 39 02 9650314 www ditec it ditec ditecva com 3 4 6 2 1 5 ...

Page 2: ...2 3 7 MP1 REX TEN MP1 MECHANICAL INSTALLATION ...

Page 3: ...3 3 7 MP1 VALOR VALORHH VALORHS MP1 ...

Page 4: ... described on page 8 9 10 11 Connect the button to terminals 1 3B 0 1 3B 27 Connection of partial opening sensor or but ton outer side The closure of the contact causes the door to open partially Connect the sensor to terminals 0 1 27 3B Connect the button to terminals 27 3B 4 1 Connection of closing command The closure of the contact causes the closing of the door 1 KOKC KC Connection of opening ...

Page 5: ... contact during the closure manoeuvre causes the movement to invert re opening Connect the device to terminals 0 1 8B 41 as described on page 8 9 10 11 NOTE make a jumper for terminals 8B 41 if the sensor is not used 1 9 29 29 Connection of the STOP command All movements are stopped when the con tact is opened All normal or emergency op erations are excluded when the contact is opened WARNING when...

Page 6: ... opens and remains open the door remains closed if it is set in NIGHT mode or with contact 1 9 open and the BST contact of the control panel is closed The alarm signalling via the visual and or acoustic device connected as described on page 8 9 10 11 continues as long as the abnormal situation persists It is possible to reset the alarm condition contact 1 29 POWER RESET of the control panel using ...

Page 7: ... contact C NO DOOR LIGHTS All the inputs are deactivated RQQHFW WKH UH VPRNH VHQVRU WR WHUPLQDOV 1 G2 1 KOKC KC 7KH FORVLQJ RI WKH FRQWDFW GXULQJ WKH UH alarm phase causes the emergency opening of the door After the set automatic closing time the door closes slowly 1 KOKC KO 7KH FORVXUH RI WKH FRQWDFW GXULQJ WKH UH alarm phase causes the emergency closure of the door After the set automatic closin...

Page 8: ... V Left opening safety Right opening safety 3 24 V 4 24 V Door lights 24 V Stop Power reset Key open Closing Key close Battery status 24 V Pass signal 24 V NONC C General purpose Internal closing safety External closing safety 0 1 3A 27 0 1 3B 27 4 1 1 KOKC PTS 0 1 1 6A 6B 41 1 9 29 BST 1 G1G2 0 1 1 8A 8B 41 1 LM LC A B C D ON OFF 1 2 3 4 J4 J5 5 24 V 6 J1J2J3 0 1 1 2 3A 3B 9 27 28 29 ON OFF 1 2 3...

Page 9: ...g safety 3 24 V 4 24 V Door lights 24 V Stop Power reset Key open Closing Key close Battery status 24 V Pass signal 24 V NONC C General purpose Internal closing safety External closing safety 0 1 3A 27 0 1 3B 27 4 1 1 KOKC PTS 0 1 1 6A 6B 41 1 9 29 BST 1 G1G2 0 1 1 8A 8B 41 1 LM LC A B C D ON OFF 1 2 3 4 J4 J5 5 24 V 6 J1J2J3 0 1 1 2 3A 3B 9 27 28 29 ON OFF 1 2 3 4 5 6 SA POWER ALARM IN VA R1 VC T...

Page 10: ...ing safety 3 24 V 4 24 V Door lights 24 V Stop Power reset Key open Closing Key close Battery status 24 V Pass signal 24 V NONC C General purpose Internal closing safety External closing safety 0 1 3A 27 0 1 3B 27 4 1 1 KOKC PTS 0 1 1 6A 6B 41 1 9 29 BST 1 G1G2 0 1 1 8A 8B 41 1 LM LC A B C D ON OFF 1 2 3 4 J4 J5 5 24 V 6 J1J2J3 0 1 1 2 3A 3B 9 27 28 29 ON OFF 1 2 3 4 5 6 SA POWER ALARM IN VA R1 VC...

Page 11: ...atus 24 V Pass signal 24 V NONC C General purpose 0 1 3A 27 0 1 3B 27 4 1 1 KOKC PTS 0 1 1 6A 6B 41 1 9 29 BST 1 G1G2 0 1 1 8A 8B 41 1 LM LC A B C D ON OFF 1 2 3 4 J4 J5 J1J2J3 0 1 1 2 3A 3B 9 27 28 29 ON OFF 1 2 3 4 5 6 SA POWER ALARM IN VA R1 VC TC RP OPEN 0 1 6 8 41 R1SRR2 P1SP P2 0 1 21 22 CELPR P1 R1 External push button Internal push button Stop Power reset WARNING do not use the terminal bo...

Page 12: ...2860 Fax 33 1 64532861 www ditecfrance com DITECGOLDPORTA ERMESINDE PORTUGAL Tel 351229773520 Fax 351229773528 38 www goldporta com DITECSWITZERLAND BALERNA Tel 41 848 558855 Fax 41 91 6466127 www ditecswiss ch DITEC ENTREMATIC NORDIC LANDSKRONA SWEDEN Tel 46 418 514 50 Fax 46 418 511 63 www ditecentrematicnordic com DITEC TURCHIA ISTANBUL Tel 90 21 28757850 Fax 90 21 28757798 www ditec com tr DIT...

Reviews: