Pg. 43
HA8-LP Manual V. 4.0
FUNCTION
LED
SETTING
LED
FUNCTION DESCRIPTION
F.A. & H.C.
DEFAULT
SETTING
0
0 to F
0 = slowest
F = fastest
OPENING SPEED
A
1
0 to 5
0 = slowest
5 = fastest
BACK CHECK SPEED
1
2
0 to 5
0 = slowest
5 = fastest
LATCH SPEED
5
3
0 to 9
0 = slowest
9 = fastest
HOLD SPEED
2
4
1 = 2 sec
2 = 4 sec
3 = 6 sec
4 = 8 sec
5= 10 sec
6 = 12 sec
7 = 14 sec
8 = 16 sec
9 = 18 sec
A = 20 sec
b = 22 sec
C = 24 sec
d = 26 sec
E = 28 sec
F = 30 sec
ACTIVATION TIME
The time that the door remains open, starting when
the activation trigger goes OFF. 2 to 30 sec
4
5
0 = 2 sec
1 = 4 sec
2 = 6 sec
3 = 8 sec
4 = 10 sec
5 = 12 sec
6 = 14 sec
7 = 16 sec
DELAY ON OPERATE
The time delay before operating the door, starting
when ACT’N2 trigger goes ON. 2 to 16 sec
This is valid when Setting A1 has the LED OFF.
1
6
0 = Instant trigger - extremely sensitive
1 = 1/8 sec - very sensitive
2 = 1/4 sec
3 = 3/8 sec - mid range sensitivity
4 = 1/2 sec
5 = 5/8 sec - not sensitive
PUSH AND GO SENSITIVITY
The amount of time that a Push and Go trigger must
be sensed before the door is triggered.
A longer time makes the door less sensitive to a
Push and Go.
3
7
1 = 1 sec
2 = 2 sec
3 = 3 sec
4 = 4 sec
5 = 5 sec
6 = 6 sec
7 = 7 sec
8 = 8 sec
9 = 9 sec
A = 10 sec
b = 12 sec
C = 14 sec
d = 15 sec
E = 25 sec
F = 30 sec
PUSH AND GO ACTIVATION TIME
The time that the door remains open starting when
the Push and Go input is triggered.
5
8
0 = 0sec
1 = .50sec
2 = 1.00sec
3 = 1.50sec
4 = 2.00sec
SAFETY 1 INHIBIT
The time that a Safety1 input is ignored (inhibited),
starting when the door goes into Latch.
0
9
0 = 0.125sec
1 = 0.25sec
2 = 0.50sec
3 = 1.00sec
4 = 1.50sec
5 = 2.00sec
STRIKE DELAY
The time between Strike ON and
door starting to open.
HA board ONLY