Entrematic Canada Inc.
Toll Free: 1-877-348-6837
info.ditec.ca@entrematic.com
www.ditecentrematic.ca
Entrematic USA Inc.
Toll Free: 1-866-901-4284
info.ditec.us@entrematic.com
www.ditecentrematic.us
Pg. 15
HA8-LP Manual V. 4.0
Push Header
The Header Box on push installations is mounted flush to the bottom of the doorjamb header. It may require solid backing
material to compensate for the thickness of the door frame. Before fastening header box to the door frame, ensure that
your access holes for high and low voltage wires match. Header box should be mounted to the hinge side of the door.
For most applications, the header is equal to door opening plus 3”. This allows for a 1½” space on either side of the
Header Box to anchor the header box properly to the frame. The header box should be anchored with a minimum of
(6) Six, #14 x
1” Pan Quad Type A screws (provided.)
•
The locations of the screws on the header will be application dependent.
•
Fasten the header body as application requires.
The header must support 200lbs.
•
Do Not use Drywall Screws or Hollow Wall Anchors to mount the Back Plate / Header.
•
Header MUST be installed 1.5 inches from hinge side for all Push/ Pull installation, regardless of
whether header is sized appropriately to door opening.
•
For Push application with standard arm, the reveal is up to
14”. For greater reveal, extended arm
is needed.
HEADER LENGTH = DOOR OPENING WIDTH + 3in [76mm]
1.50in 38mm IMPORTANT
1.50in 38mm
HINGE
STILE
DEPENDING ON OPTION
~2in or ~3in [~51mm or ~76mm]
PUSH ARM DOOR SHOE
14in
356mm
DOOR OPENING WIDTH
STRIKE
SIDE
2.89in [74mm] DISTANCE BETWEEN HEADER END CAP
AND BOTTOM GEARBOX BRACKET (SEE SECTION 2.5)
2.0 OPERATOR INSTALLATION