8
IP2270EN
EN
8. Regular safety checks
To meet the national/international requisites and avoid any risk of personal injury or
device malfunctioning, the following check-list is supplied.
Do not use when repairs or adjustments need to be carried out.
Disconnect the power supply [A] when carrying out cleaning or maintenance tasks.
Daily tasks
In the event of
problems
Activate the automation and visually check the fixing of:
• the automation [1]
• the cables
• the function selectors [6]
• the door and glass
Check the automation, and visually check:
• the condition of the door gaskets
• the presence of the finger guard
• that the door is working correctly, and closes slowly and smoothly
Set the program selector on DOOR CLOSED
and check the automation and electro-
mechanical lock (if installed) are working in synch.
Check the door hooks up to the locking device properly.
Activate the manual command devices, if installed.
Approach the door and check it opens correctly via the automatic command devices [2].
Check the photocells [5] / safety sensors [2, 4] by standing in the path of the opening/closing
door and activating the automation.
As it opens and closes, the door must not hit the person carrying out the check.
= adopt suitable measures
= contact the Entrematic Customer Technical Service.
1
3
2
5
A
6
4
4
Summary of Contents for Ditec DAS107PLUS
Page 1: ...Ditec DAS107PLUS User Manual www entrematic com IP2270 2018 07 17 ...
Page 2: ...Italiano English Deutsch Español Português Pусский Türkçe ...
Page 13: ...Ditec DAS107PLUS User Manual www entrematic com IP2270EN 2018 07 17 ...
Page 23: ...Schiebetüren Ditec DAS107 Benutzerhandbuch www entrematic com IP2270DE 2018 07 17 ...
Page 33: ...Ditec DAS107PLUS Manual para el usuario www entrematic com IP2270ES 2018 07 17 ...
Page 43: ...Ditec DAS107PLUS Manual para o utilizador www entrematic com IP2270PT 2018 07 17 ...
Page 53: ...Ditec DAS107PLUS Руководство пользователя www entrematic com IP2270RU 2018 07 17 ...
Page 63: ...Ditec DAS107PLUS Kullanıcı Kılavuzu www entrematic com IP2270TK 2018 07 17 ...
Page 73: ......
Page 74: ...IP2270EN Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www entrematic com ...