background image

              

Service and Installation Manual

 

                                                            For warranty service, call 866-417-6140  

   

3.    ALARM SIGNALS                                                                                                                                                                   

 
HOW TO SEE THE ALARM AND   
RESET THE RECORDED ALARM 

1. Push the 

  or 

  key, the   

alarm signals are displayed; 
2. When the signal is displayed, hold   
the 

SET

 key until the “rst” message   

is displayed, and push the 

SET

 key   

again, the “rst” message start   
blinking and the normal temperature   
will be displayed again. 

MAINTENANCE                                                                                                                   

The power switch must be turned to OFF and the unit disconnected from the 
power source whenever performing service, maintenance functions or cleaning 
the refrigerated area.

 

 

Refrigerators 

The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and 
water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the "grain" of the stainless 
steel to avoid marring the finish. 

Do not use an abrasive cleaner because it will scratch the stainless steel and plastic and can damage the 
breaker strips and gaskets. 

Cleaning the Condenser Coil

 

The condenser coil requires regular cleaning, recommended is every 90 days. In some instances, you may 
find that there is a large amount of debris and dust or grease accumulated prior to the 90 day time frame. In 
these cases the condenser coil should be cleaned every 30 days. 

If the build up on the coil consists of only light dust and debris the condenser coil can be cleaned with a 
simple brush, heavier dust build up may require a vacuum or even compressed air to blow through the 
condenser coil. 

If heavy grease is present, there are de-greasing agents available for refrigeration use and specifically for 
the condenser coils. The condenser coil may require a spray with the de-greasing agent and then blown 
through with compressed air. 

Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times, 
continuous operation with dirty or clogged condenser coils can result in compressor failures. Neglecting the 
condenser coil cleaning procedures will void any warranties associated with the compressor or cost to 
replace the compressor. 

Never use a high pressure water wash for this cleaning procedure as water can 
damage the electrical components located near or at the condenser coil. 

 

In order to maintain proper refrigeration performance, the condenser fins must be cleaned of dust, dirt and 
grease regularly. It is recommended that this be done at least every three months. If conditions are such that 
the condenser is totally blocked in three months, the frequency of cleaning should be increased. Clean the 
condenser with a vacuum cleaner or stiff brush. If extremely dirty, a commercially available condenser 
cleaner may be required. 

 

Summary of Contents for BCBD1

Page 1: ...ual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately I M P O R T A N T I N F O R M A T I O N R E A D B E F O R E U S E PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...ed and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by the shipping company of the damaged equipment This should be done wi...

Page 3: ...ack and side to side Units supplied with legs will have adjustable bullet feet to make the necessary adjustments If the unit is supplied with casters no adjustments are available Ensure the floor where the unit is to be located is level Stabilizing Models are supplied on casters for your convenience ease of cleaning underneath and for mobility It is very important however that the cabinet be insta...

Page 4: ... 2 Push and immediately release the SET key or wait for 5 seconds to display the sensor value again 2 2 HOW TO CHANGE THE SETPOINT 1 Push the SET key for more than 2 seconds to change the set point value 2 The value of the set point will be displayed and the LED starts blinking 3 To change the set value push the or key within 10s 4 To memory the new set point value and push the SET key again or wa...

Page 5: ...oil should be cleaned every 30 days If the build up on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush heavier dust build up may require a vacuum or even compressed air to blow through the condenser coil If heavy grease is present there are de greasing agents available for refrigeration use and specifically for the condenser coils The condenser...

Page 6: ...Common items include tomatoes peppers and other vegetables Gasket Maintenance Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soapy water Avoid full strength cleaning products on gaskets as this can cause them to become brittle and prevent proper seals Also never use sharp tools or k...

Page 7: ...e bottom hinge pin DIRECT DRAW DRAFT ARM INSTALLATION On direct draws the drain is located at the front of the cabinet To plumb in the drain connect P V C pipe to the barbed fitting supplies with the unit INSTALLING C02 CYLINDER AND REGULATOR Make certain that all fittings in system are tight Always keep the CO2 cylinder in vertical position The recommended pressure for the CO2 system is 8 10 psi ...

Page 8: ... D Sharp Keg Tap 3 Beer Line 4 Beer Dispenser 5 CO2 Line 6 CO2 Tee Joint 7 CO2 Regulator 8 CO2 Cylinder 9 CO2 Line 1 10 CO2 Line 2 ONE DOOR CO2 KNOCK OUT This instruction is the procedure for installing a remote CO2 container for one door unit REQUIRED TOOLS Pliers Power Drill Silicone Sealer Drill bit 1 2 STEP 1 Remove black knockout plug with a pair of pliers NOTE Knockout plug for CO2 line can ...

Page 9: ...ly sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from the manufacturer Removal or defacement of the original Serial Number or Model Number from any Unit shall be deemed to re...

Page 10: ...n case of warranty compressor the compressor warranty form must be filled out by a qualified refrigeration technician This form can be obtain by down load from our website www entree biz This form must be emailed in its completion with a copy of the original proof of purchase to john entree biz WHAT IS NOT COVERED BY THIS WARRANTY Entrée L L C sole obligation under this warranty is limited to eith...

Page 11: ...nstallation fire flood or act of God IMPROPER ELECTRICAL CONNECTIONS ENTRÉE L L C IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM INCORRECT SUPPLY VOLTAGE THE USE OF EXTENSION CORDS LOW VOLTAGE OR UNSTABLE SUPPLY VOLTAGE THE USE OF PIERCING VALVES IS PROHIBITED AND IF LEFT IN THE SYSTEM VOIDS ALL WARRANTIES THIS EQUIPMENT IS INTENDED FOR INDOOR USE O...

Page 12: ...Service and Installation Manual For warranty service call 866 417 6140 12 ENTRÉE LLC 4673 OSBORNE DR SUITE I EL PASO TX 79922 Technical Support 570 752 4602 www entree biz ...

Reviews: