background image

                                                                                                     

Service and Installation Manual

 

    For warranty service, call 866-417-6140                                                                                                 

CONTENTS

 

                                                                       

RECEIVING & INSPECTING EQUIPMENT --------------------------------------------------------- 2 
SPECIFICATIONS ----------------------------------------------------------------------------------------- 2 
INSTALLATION --------------------------------------------------------------------------------------------- 3 
OPERATION ------------------------------------------------------------------------------------------------- 3-4 
MAINTENANCE -------------------------------------------------------------------------------------------- 5-6 
WARRANTY INFORMATION ---------------------------------------------------------------------------- 10 

All rights reserved. Reproduction without written permission is prohibited.                           

SERIAL NUMBER INFORMATION                                                                             

The serial number of all self-contained refrigerators and freezers is located inside the unit on the left hand 
side near the top on the wall. Always have the serial number of your unit available when calling for parts or 
service. 
 
This manual covers standard units only. If you have a custom unit, consult the customer service department 
at the number listed on the last page. 

RECEIVING AND INSPECTING THE EQUIPMENT                                             

Even though most equipment is shipped crated, care should be taken during unloading so the equipment is 
not damaged while being moved into the building. 

1. Visually  inspect  the  exterior  of  the  package  and  skid  or  container.  Any  damage  should  be  noted  and 

reported to the delivering carrier immediately. 

2. If damaged, open and inspect the contents with the carrier. 
3. In  the  event  that  the  exterior  is  not  damaged,  yet  upon  opening,  there  is  concealed  damage  to  the 

equipment notify the carrier. Notification should be made verbally as well as in written form. 

4. Request an inspection by the shipping company of the damaged equipment. This should be done within 

10 days from receipt of the equipment. 

5.  Be certain to check the compressor compartment housing and visually inspect the refrigeration package. 

Be sure lines are secure and base is still intact. 

6. Freight carriers can supply the necessary damage forms upon request.   
7. Retain all crating material until an inspection has been made or waived. 

                                                         

SPECIFICATION

                                                                   

BEER DISPENSERS 

MODEL# 

V/Hz/Ph  AMPS 

STORAGE 

CAPACITY 

Cu-ft 

HP 

BTU 

 

CHARGE 

OZ 

SHIP 

WEIGHT 

LBS 

 
NEMA 
PLUG 

BCBD1 

115/60/1 

2.5 

7.2

1/8

740

2.82

161 

5-15P

BCBD2-1 

115/60/1 

3.2 

10.45

2/5

1155

8.05

264 

5-15P

BCBD2-2 

115/60/1 

3.2 

10.45

2/5

1155

8.05

267 

5-15P

BCBD3-1 

115/60/1 

3.2 

14.16

2/5

1155

8.05

302 

5-15P

BCBD3-2 

115/60/1 

3.2 

14.16

2/5

1155

8.05

304 

5-15P

BCBD4-2 

115/60/1 

3.5 

17.26

1/2

1771

8.05

351 

5-15P

 

 
 
 
 

Summary of Contents for BCBD1

Page 1: ...ual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately I M P O R T A N T I N F O R M A T I O N R E A D B E F O R E U S E PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...ed and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by the shipping company of the damaged equipment This should be done wi...

Page 3: ...ack and side to side Units supplied with legs will have adjustable bullet feet to make the necessary adjustments If the unit is supplied with casters no adjustments are available Ensure the floor where the unit is to be located is level Stabilizing Models are supplied on casters for your convenience ease of cleaning underneath and for mobility It is very important however that the cabinet be insta...

Page 4: ... 2 Push and immediately release the SET key or wait for 5 seconds to display the sensor value again 2 2 HOW TO CHANGE THE SETPOINT 1 Push the SET key for more than 2 seconds to change the set point value 2 The value of the set point will be displayed and the LED starts blinking 3 To change the set value push the or key within 10s 4 To memory the new set point value and push the SET key again or wa...

Page 5: ...oil should be cleaned every 30 days If the build up on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush heavier dust build up may require a vacuum or even compressed air to blow through the condenser coil If heavy grease is present there are de greasing agents available for refrigeration use and specifically for the condenser coils The condenser...

Page 6: ...Common items include tomatoes peppers and other vegetables Gasket Maintenance Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soapy water Avoid full strength cleaning products on gaskets as this can cause them to become brittle and prevent proper seals Also never use sharp tools or k...

Page 7: ...e bottom hinge pin DIRECT DRAW DRAFT ARM INSTALLATION On direct draws the drain is located at the front of the cabinet To plumb in the drain connect P V C pipe to the barbed fitting supplies with the unit INSTALLING C02 CYLINDER AND REGULATOR Make certain that all fittings in system are tight Always keep the CO2 cylinder in vertical position The recommended pressure for the CO2 system is 8 10 psi ...

Page 8: ... D Sharp Keg Tap 3 Beer Line 4 Beer Dispenser 5 CO2 Line 6 CO2 Tee Joint 7 CO2 Regulator 8 CO2 Cylinder 9 CO2 Line 1 10 CO2 Line 2 ONE DOOR CO2 KNOCK OUT This instruction is the procedure for installing a remote CO2 container for one door unit REQUIRED TOOLS Pliers Power Drill Silicone Sealer Drill bit 1 2 STEP 1 Remove black knockout plug with a pair of pliers NOTE Knockout plug for CO2 line can ...

Page 9: ...ly sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from the manufacturer Removal or defacement of the original Serial Number or Model Number from any Unit shall be deemed to re...

Page 10: ...n case of warranty compressor the compressor warranty form must be filled out by a qualified refrigeration technician This form can be obtain by down load from our website www entree biz This form must be emailed in its completion with a copy of the original proof of purchase to john entree biz WHAT IS NOT COVERED BY THIS WARRANTY Entrée L L C sole obligation under this warranty is limited to eith...

Page 11: ...nstallation fire flood or act of God IMPROPER ELECTRICAL CONNECTIONS ENTRÉE L L C IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM INCORRECT SUPPLY VOLTAGE THE USE OF EXTENSION CORDS LOW VOLTAGE OR UNSTABLE SUPPLY VOLTAGE THE USE OF PIERCING VALVES IS PROHIBITED AND IF LEFT IN THE SYSTEM VOIDS ALL WARRANTIES THIS EQUIPMENT IS INTENDED FOR INDOOR USE O...

Page 12: ...Service and Installation Manual For warranty service call 866 417 6140 12 ENTRÉE LLC 4673 OSBORNE DR SUITE I EL PASO TX 79922 Technical Support 570 752 4602 www entree biz ...