Safety Compliance
Power Cord Safety
Please
read
the
following
safety
information
carefully
before
installing
the
access
point:
WARNING:
Installation
and
removal
of
the
unit
must
be
carried
out
by
qualified
personnel
only.
•
The
unit
must
be
connected
to
an
earthed
(grounded)
outlet
to
comply
with
international
safety
standards.
•
Do
not
connect
the
unit
to
an
A.C.
outlet
(power
supply)
without
an
earth
(ground)
connection.
•
The
appliance
coupler
(the
connector
to
the
unit
and
not
the
wall
plug)
must
have
a
configuration
for
mating
with
an
EN
60320/IEC
320
appliance
inlet.
•
The
socket
outlet
must
be
near
to
the
unit
and
easily
accessible.
You
can
only
remove
power
from
the
unit
by
disconnecting
the
power
cord
from
the
outlet.
•
This
unit
operates
under
SELV
(Safety
Extra
Low
Voltage)
conditions
according
to
IEC
60950.
The
conditions
are
only
maintained
if
the
equipment
to
which
it
is
connected
also
operates
under
SELV
conditions.
France
and
Peru
only
This
unit
cannot
be
powered
from
IT
†
supplies.
If
your
supplies
are
of
IT
type,
this
unit
must
be
powered
by
230
V
(2P+T)
via
an
isolation
transformer
ratio
1:1,
with
the
secondary
connection
point
labelled
Neutral,
connected
directly
to
earth
(ground).
†
Impédance
à
la
terre
Important!
Before
making
connections,
make
sure
you
have
the
correct
cord
set.
Check
it
(read
the
label
on
the
cable)
against
the
following:
Power Cord Set
U.S.A. and Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A.
The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125 V) or
NEMA 6-15P (15 A, 250 V) configuration.
Denmark
The supply plug must comply with Section 107-2-D1, Standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
U.K.
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fuse which
complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (mini-
mum).
Europe
The supply plug must comply with CEE7/7 (“SCHUKO”).
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (mini-
mum).
IEC-320 receptacle.