Enterasys Networks recommends labeling fiber-optic cables to indicate receive and transmit ends.
Many cables are pre-labeled, providing matching labels or tapes at both ends of each strand of
cable.
To connect an LC cable connector to a fixed LC connector of a Mini-GBIC, refer to
Figure 3-13
and proceed as follows:
1. Remove the protective covers (not shown) from the front panel LC fiber-optic port
(port 52
in this example) and from the connectors
on each end of the cable.
2. Insert the LC cable connector
into the LC connector
until it clicks into place.
NOTE: Leave the protective covers in place when the connectors are not in use to
prevent contamination.
CAUTION: Do not touch the ends of the fiber-optic strands, and do not let the ends
come in contact with dust, dirt, or other contaminants. Contamination of cable ends
causes problems in data transmissions. If the ends of the fiber-optic strands become
contaminated, use a canned duster to blow the surfaces clean. A fiber-port cleaning
swab saturated with optical-grade isopropyl alcohol may also be used to clean the ends.
NOTE: To remove the LC cable connector
, press on its release tab
and pull out
the cable connector.