Installing Optional Mini-GBICs
3-4
Hardware Installation
Figure 3-2
Mini-GBIC with LC Connector (C1H124-48 shown)
Removing the Mini-GBIC
To remove a Mini-GBIC from the C1H124-48
port slot, proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap package)
before removing the Mini-GBIC.
2. Remove the cables connected to the Mini-GBIC.
3. Locate the release tab
under the front end of the Mini-GBIC
. For the type of Mini-GBIC
shown in
Figure 3-1
, push in on the release tab as far as it will go to release the Mini-GBIC from
the port slot
. For the type of Mini-GBIC shown in
Figure 3-2
, pull out on the release tab to
release the Mini-GBIC from the port slot.
Mini-GBIC
(MGBIC-LC01 and MGBIC-LC09)
Port slot
Mini-GBIC
,
top side
Mini-GBIC
,
protective dust cover
7-Pin edge connector (insertion side)
Release tab
CAUTION: Carefully follow the instructions in this manual to avoid damaging the
Mini-GBIC and the host device (C1H124-48
or
C1G124-24).
The Mini-GBIC and host device are sensitive to static discharges. Use an antistatic wrist
strap and observe all static precautions during this procedure. Failure to do so could
result in damaging the Mini-GBIC or host device. Always leave the Mini-GBIC in the
antistatic bag or an equivalent antistatic container when not installed.
Â
Á
À
Å
3831_01_02A
CPU RPS
1
49
51
2
50
52
1
2
52
50
49
51
Ã
Ä