Installing the Device
3-6
Hardware Installation
3.4.1
Rackmount Installation
To install the device in a 19-inch rack, you need:
•
Two rackmount brackets and mounting screws (rackmount kit) shipped with the device.
•
Four user-supplied screws to attach the device to a standard 19-inch rack.
3.4.1.1
Guidelines for Rackmount Installation
The installation site must be within reach of the network cabling and meet the requirements listed
below:
•
Appropriate grounded power receptacles must be located within seven feet of the location.
•
An ambient temperature between 5
°
C (41
°
F) and 40
°
C (104
°
F) must be maintained at the
installation site with fluctuations of less than 10
°
C (18
°
F) per hour.
3.4.2
Rack Mounting the Device
Proceed as follows to install the device into a 19-inch rack:
1. Attach the rackmount brackets
to the device, as shown in
Figure 3-4
, using the eight
M3 x 10 mm flathead screws
in the rackmount kit.
Figure 3-4
Attaching the Rackmount Brackets
CAUTION: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the device.
WARNING: Before installing the device
into a rack, ensure that the rack can support the
device(s) without compromising the stability of the rack. Otherwise, personal injury
and/or equipment damage may result.
Rackmount brackets
M3 x 10 mm flathead screws
CPU
RPS
1
16
17
32
33
48
49
51
2
3
4
5
6
7
8
9
10
1
1
12
13
14
15
18
19
20
21
22
23
24
25
26
27
28
29
30
31
34
35
36
37
38
39
40
41
42
43
44
45
46
47
50
52
1
2
47
48
52
50
49
51
V1H124-48
3831_00_04
Á
À