
Connecting to the Network
Matrix DFE-Gold Series PoE Module 4H4285-49 Installation Guide 3-13
Connecting to the Network
This
section
provides
the
procedures
for
connecting
unshielded
twisted
pair
(UTP)
segments
from
the
network
or
other
devices
to
the
4H4285
‐
49
(
“Connecting
UTP
Cables
to
4H4285
‐
49”
on
page 3
‐
13).
Connecting UTP Cables to 4H4285-49
The
fixed
RJ45
front
panel
connections
of
the
4H4285
‐
49
are
10/100
Mbps
ports.
The
ports
have
internal
crossovers,
and
also
support
automatic
‐
polarity
sensing
when
configured
for
automatic
‐
negotiation.
If
automatic
‐
negotiation
is
not
activated
on
a
port,
use
a
straight
‐
through
cable
when
connecting
a
workstation
to
the
port.
When
connecting
a
networking
device
to
the
port,
such
as
a
bridge,
repeater,
or
router,
use
a
crossover
cable.
If
a
port
is
set
for
auto
‐
negotiation,
automatic
‐
polarity
sensing
is
also
activated.
Automatic
‐
polarity
sensing
eliminates
the
need
for
a
crossover
cable,
regardless
if
the
connection
is
to
another
network
device
or
a
workstation.
The
fixed
RJ45
front
panel
connectors
of
the
4H4285
‐
49
also
support
PoE
‐
compliant
connections
to
PDs
(powered
devices)
that
require
48
Vdc
through
the
UTP
cable
to
operate.
Whether
the
48
Vdc
is
available
through
the
backplane
of
an
N5
chassis
or
externally
from
an
N
‐
POE
Power
System,
you
can
verify
if
there
is
power
at
each
port
as
described
later
in
this
procedure.
Making the UTP Connections
Note:
If the DFE module is being installed in a network using Link Aggregation, there are
rules concerning the network cable and port configurations that must be followed for Link
Aggregation to operate properly. Before connecting the cables, refer to the
Enterasys
Matrix DFE-Gold Series Configuration Guide
for the configuration information. For details
on how to obtain manuals, refer to
“Related Documents”
on page xvi.
Note:
All RJ45 front panel ports on the 4H4285-49
support Category 5 Unshielded
Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category 3
cable may be used if the connection is going to be used only for 10 Mbps.
Caution:
To prevent damage to the equipment, do not connect the PoE supported ports
(1 through 48) to segments running between buildings. Keep connections to equipment
within the building.
Precaución:
Para evitar que el equipo se dañe, no conecte los puertos PoE
(1 a 48) a segmentos que vayan de un edificio a otro. Mantenga las conexiones de los
equipos dentro del edificio.
Summary of Contents for 6H308-48
Page 2: ......
Page 12: ...x...
Page 16: ...xiv...
Page 56: ...Completing the Installation 3 28 Installation...
Page 70: ...Regulatory Compliance A 4 Specifications...
Page 88: ...PoE Port Status LEDs C 4 About PoE Power over Ethernet...