Enterasys 6H308-48 Hardware Installation Manual Download Page 24

DFE-Gold Module

1-4 Introduction

Figure 1-1  4H4285-49 DFE-Gold Module

1

OFFLINE/RESET button

7

GROUP status LEDs

2

RJ45 COM

 

(Console Port)

8

GROUP select LEDs

3

MGMT LED 

9

NEM option slot

4

CPU LED

10

48 Vdc/20 Amperes Maximum, optional power input connector

5

POE LED

11

Ports (1-48), 10/100 Mbps through RJ45 connectors

6

GROUP SELECT button

1X

G

R

O

U

P
1

G

R

O

U

P
2

11X

13X

23X

OFFLINE/

RESET

COM

CPU

MGMT

GROUP

SELECT

GROUP

1

2

3

4

5

6

7

8

9

10

11

12

POE

14X

24X

G

R

O

U

P
3

25X

35X

26X

36X

G

R

O

U

P
4

37X

47X

38X

48X

1

2

3

4

48V --- 20A MAX

 OPTIONAL

POWER INPUT

DFE

4H4285-49

FAST ENET

Æ

Å

À
Á

Â

ÃÄ

Ç

È

É

À

11

Summary of Contents for 6H308-48

Page 1: ...7 5x9 inch cover with bleed on 4 sides Enterasys Matrix DFE Gold Series Hardware Installation Guide PoE Module 4H4285 49 P N 9033989 06...

Page 2: ......

Page 3: ...2008 Enterasys Networks Inc All rights reserved Part Number 9033989 06 July 2008 ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW MATRIX ENTERASYS NETSIGHT WEBVIEW and any logos associated therewith are t...

Page 4: ...s A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits...

Page 5: ...lectrical and Electronic Equipment WEEE Notice In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that se...

Page 6: ...ous materials in the parts is above the relevant threshold of the SJ T 11363 2006 standard This table shows where these substances may be found in the supply chain of Enterasys electronic information...

Page 7: ...VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions BSMI EMC Statement Taiwan This is a c...

Page 8: ...of radiant power exiting the fiber under normal conditions is 12 6 dBm or 55 x 10 6 watts Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical p...

Page 9: ...F YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED PRODUCT T...

Page 10: ...st or iii if the direct product of the technology is a complete plant or any major component of a plant export to Country Groups D 1 or E 2 the direct product of the plant or a major component thereof...

Page 11: ...edge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate and that Enterasys may be en...

Page 12: ...x...

Page 13: ...Network 2 2 100BASE TX Network 2 2 Chapter 3 Installation Installation Site Requirement 3 2 Unpacking the DFE Module 3 2 Installing Optional Network Expansion Module NEM 3 3 DFE Module Placement and...

Page 14: ...4 10 Appendix A Specifications 4H4285 49 Specifications A 1 COM Port Pinout Assignments A 3 Regulatory Compliance A 3 Appendix B Mode Switch Settings and Option Installations Required Tools B 1 Setti...

Page 15: ...ompatible 3 19 3 10 Connecting a VT Series Terminal 3 20 3 11 Connecting Using a Modem 3 22 3 12 Matrix Defogged Startup Screen Example N7 Chassis 3 26 4 1 LANVIEW LEDs 4 2 4 2 OFFLINE RESET Switch 4...

Page 16: ...xiv...

Page 17: ...dule refers to the 4H4285 49 unless otherwise noted Network expansion module or NEM or refers to an optional uplink card installed on the main logic board and accessible through the option slot of the...

Page 18: ...d cable specifications Unlike the Enterasys Matrix DFE Gold Series Configuration Guide and the Matrix N Series N POE Power System Installation Guide the Cabling Guide is not listed alphabetically on t...

Page 19: ...Achtung Verwei t auf wichtige Informationen zum Schutz gegen Besch digungen Electrical Hazard Warns against an action that could result in personal injury or death due to an electrical hazard Riesgo...

Page 20: ...ption of your network environment for example layout cable type Network load and frame size at the time of trouble if known The device history for example have you returned the device before is this a...

Page 21: ...the firmware version used in the DFE module some features described in this document may not be supported Refer to the Release Notes shipped with the DFE module to determine which features are suppor...

Page 22: ...rvices and management Self learning configuration modules with increased reliability and fault tolerance that reduces configuration time and maximizes uptime Network wide configuration change and inve...

Page 23: ...al external Matrix N POE Power System The Matrix N POE Power System can provide 48 Vdc to support up to eight PoE compliant DFE modules The connection from the N POE Power System is by way of the 48 V...

Page 24: ...ED 10 48 Vdc 20 Amperes Maximum optional power input connector 5 POE LED 11 Ports 1 48 10 100 Mbps through RJ45 connectors 6 GROUP SELECT button 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET CO...

Page 25: ...inal emulator Switch Configuration Using WebView Enterasys Networks HTTP based Web management application WebView is an intuitive web tool for simple management tasks Switch Configuration Using CLI Co...

Page 26: ...s are used to assign Network Services to groups of users who share common needs for example Executive Managers Human Resources Personnel or Guest Users Access resources and security restrictions are a...

Page 27: ...it allows for automatic configuration with manual overrides if applicable and can operate on 10 Mbps 100 Mbps or 1000 Mbps Ethernet full duplex ports Thus the network administrator can combine a grou...

Page 28: ...formation about PoE refer to Appendix C 100BASE TX Network The fixed front panel ports of the 4H4285 49 provide a connection that supports Category 5 UTP cabling The device at the other end of the twi...

Page 29: ...lationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden Important Notice Read the Release Notes shipped with the DFE module to check for any exceptions to the supported...

Page 30: ...ct Enterasys Networks if there are any signs of damage Refer to Getting Help on page xviii for details Warning Install this module in a Matrix N3 or N7 chassis that has been installed in a Restricted...

Page 31: ...acement rules Matrix N3 Matrix N5 or Matrix N7 chassis The Matrix N3 Matrix N5 or Matrix N7 chassis support only DFE modules and there are no particular rules for installing modules Note Install any o...

Page 32: ...be due to module reset removal or failure However with the redundancy key installed the system will remain operational provided that there is an operating module in slot 1 or 2 Figure 3 1 Examples Slo...

Page 33: ...system completely as long as there is an operating module in slot 1 or 2 Example 4 Figure 3 1 D Shows a chassis populated with 4xxxxx modules in all slots except 1 and 2 This system is not operationa...

Page 34: ...sis on page 3 10 Caution Failure to observe static safety precautions could cause damage to the DFE Gold module Follow static safety handling rules and wear the antistatic wrist strap Do not cut the n...

Page 35: ...de panel posterior Aseg rese de que la palanca superior est alineada con respecto al n mero de ranura correspondiente ubicado en el panel frontal del chasis Electrical Hazard To prevent exposure to a...

Page 36: ...turn the power supplies on Check to see that the module CPU LED settles at solid green after a few minutes If the LED does not turn solid green refer to Chapter 4 for troubleshooting details Caution I...

Page 37: ...d 7 Backplane connectors power and FTM2 4 Metal back panel 1 SERIES E7 4 5 6 7 2 3 50 60Hz LINE 100 125V 12A 200 240V 6A 50 60Hz LINE 100 125V 12A 200 240V 6A ACON 1 0 POWER FAN PS1 50 60Hz LINE 100 1...

Page 38: ...s stos podr an da arse Warning Install this module in a Matrix N3 or N5 chassis that has been installed in a Restricted Access Location only Access to the equipment by users must be restricted through...

Page 39: ...tz vor el Sch den des Moduls 4H4285 49 zu gew hleisten bei Verwendung der N POE Systeme sollte dies bevor man dieses entnimmt oder Servicearbeiten daran vornimmt vom 48 Vdc Stecker getrennt werden Fig...

Page 40: ...m Advertencia El modulo DFE es embarcado con una cubierta sobre su conector de poder opcional de 48 Vdc No remover esta cubierta cuando el modulo DFE es instalado en un chassis N5 Esta cubierta debe r...

Page 41: ...owered devices that require 48 Vdc through the UTP cable to operate Whether the 48 Vdc is available through the backplane of an N5 chassis or externally from an N POE Power System you can verify if th...

Page 42: ...utton for less than one second see Figure 3 4 to step to the group of interest Groups 1 through 4 b Each time the GROUP SELECT button is pressed for less that one second the GROUP LED lights up in seq...

Page 43: ...segment have the proper pinouts and check the cable for continuity Typically a crossover cable is used between hub devices A straight through cable is used to connect between switches or hub devices...

Page 44: ...ugh cable 2 Other device port 4 RX RX and TX TX connections These connections must share a common color pair Figure 3 7 Eight Wire Crossover Cable RJ45 Pinouts Connections Between Hub Devices 1 RJ45 d...

Page 45: ...85 49 RJ45 port ensure that there is power at the RJ45 port as follows 1 Press on the GROUP SELECT button for more than one second The 4H4285 49 will enter the PoE status mode which will indicate a se...

Page 46: ...er you can connect products equipped with an RJ45 COM port to an IBM or compatible PC running a VT series emulation software package With a UTP straight through cable and RJ45 to DB25 female adapter y...

Page 47: ...a VT Series Terminal To connect a VT Series terminal to an Enterasys Networks DFE module COM port Figure 3 10 use a UTP straight through cable with RJ45 connectors and an RJ45 to DB25 female adapter...

Page 48: ...access the Setup Directory Set the following parameters on your terminal When these parameters are set the Local Management password screen will display Refer to the Enterasys Matrix DFE Gold Series C...

Page 49: ...connector at the other end of the UTP straight through cable into the RJ45 to DB25 modem adapter 3 Connect the RJ45 to DB25 adapter to the communications port on the modem 4 Turn on the modem 5 With...

Page 50: ...Figure 3 11 Connecting Using a Modem 1 UTP straight through cable with RJ45 connectors 4 Local modem 2 RJ45 COM port 5 Remote modem 3 RJ45 to DB25 modem adapter 6 PC 1X G R O U P 1 OFFLINE RESET COM C...

Page 51: ...RX 4 Red 3 Transmit TX 5 Green 5 Ground GRD 2 Orange 7 Request to Send RTS 6 Yellow 8 Clear to Send CTS VT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Pin Conductor Pin Signal 4 Red 2 Tran...

Page 52: ...es will automatically be set to the factory default values A complete list of the factory default values are provided in Chapter 3 of the Enterasys Matrix DFE Gold Series Configuration Guide After ins...

Page 53: ...bout setting the IP address and configuring Telnet settings for remote access to DFE module management refer to Chapter 3 in the Enterasys Matrix DFE Gold Series Configuration Guide The CLI commands e...

Page 54: ...accordingly If you need to change any settings you can connect a terminal to the local console port as described in Connecting to COM Port for Local Management on page 3 18 to access system managemen...

Page 55: ...apter 3 in the Enterasys Matrix DFE Gold Series Configuration Guide The CLI commands enable you to initially set up and perform more involved management configurations The Enterasys Matrix DFE Gold Se...

Page 56: ...Completing the Installation 3 28 Installation...

Page 57: ...agement functions for all DFE Gold modules in the chassis The Management Module handles all IP requests to the chassis IP address such as PING Telnet SNMP HTTP and more The Management Module also hand...

Page 58: ...GROUP SELECT button see Figure 4 1 to step to the group of interest Groups 1 through 4 Each time the GROUP SELECT button is pressed the GROUP LED lights up in sequence indicating which group is select...

Page 59: ...gment If there is power at the port the RX LED is green and the TX LED is off Otherwise refer to Table 4 1 for troubleshooting information 3 Press the GROUP SELECT button again for more than two secon...

Page 60: ...s that the module is in the process of shutting down None This state is activated when the OFFLINE RESET switch is pressed for less than 1 second to start the process of an orderly shutdown While in t...

Page 61: ...llisions This indication is only supported on 10 100 ports Contact Enterasys Networks for technical support TX Transmit Off Port enabled but no activity If it is known that the port should be active a...

Page 62: ...asys Networks for technical support Red Off Port is off due to PoE power management Port may be turned off due to priority or other administration configuration None Off Off Port is off for other reas...

Page 63: ...clear NVRAM Cannot navigate beyond Password screen Improper username password combination entered If the username password combination has been forgotten refer to Refer to Setting the Mode Switches o...

Page 64: ...the front panel OFFLINE RESET switch was pressed Position of Mode switch 7 Persistent Data Reset was changed sometime before either cycling power or pressing the OFFLINE RESET switch causing the user...

Page 65: ...ligent decisions and stabilize the network before the change is made thereby increasing network availability You can shut down a DFE module in an operating system using the OFFLINE RESET switch shown...

Page 66: ...E RESET switch for approximately 6 seconds Pulling any DFE module out of the chassis before it has been shut down is not recommended The only safe time to pull a module out of the chassis is after the...

Page 67: ...ory physical and environmental module specifications for DFE Gold module 4H4285 49 For information about Refer to page 4H4285 49 Specifications A 1 COM Port Pinout Assignments A 3 Regulatory Complianc...

Page 68: ...2 38 W x 11 62 D in Approximate Weight Gross 5 54 kg 12 0 lb shipping carton containing one module Net 4 10 kg 9 0 lb one module without packaging Predicted hours for Mean Time Between Failures MTBF F...

Page 69: ...Table A 3 Table A 2 COM Port Pin Assignments Pin Signal Name Input Output 1 Transmit Data XMT Output 2 Clear to Send CTS Input 3 Data Set Ready DSR Input 4 Receive Data RCV Input 5 Signal Ground GND N...

Page 70: ...Regulatory Compliance A 4 Specifications...

Page 71: ...r to page Required Tools B 1 Setting the Mode Switches B 2 Memory Locations and Replacement Procedures B 3 Gaining Access to Memory Modules B 4 Caution An antistatic wrist strap is required to perform...

Page 72: ...r use the factory default settings or reenter your own parameters Switch 8 Clear Admin Password Changing the position of this switch clears the admin password and restores the factory default password...

Page 73: ...e memory modules If you have questions concerning the replacement of either memory module refer to Getting Help on page xviii for details on how to contact Enterasys Networks Figure B 2 shows the DIMM...

Page 74: ...48V 20A MAX OPTIONAL POWER INPUT 4H4285 49 FAST ENET DFE 1 2 3 4 5 6 1 2 3 4 5 6 7G 6MGBIC A Electrical Hazard To prevent exposure to an energy hazard in a 4H4285 49 connected to an external N POE Po...

Page 75: ...cover 4 If you are replacing the DRAM SIMM proceed to DRAM SIMM Replacement Procedure on page B 7 If you need to replace the DIMM proceed to DIMM Replacement Procedure on page B 10 Warning The safety...

Page 76: ...crews 7 4 Standoff spacer screwed to standoff under the interface board 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM CPU MGMT GROUP SELECT GROUP 1 2 3 4 5 6 7 8 9 10 11 12 POE 12 X 14X 24X...

Page 77: ...the Optional Network Expansion Module Caution Observe all Electrostatic Discharge ESD precautions when handling sensitive electronic equipment Precauci n Al trabajar con equipos electr nicos sensible...

Page 78: ...ors Now you have access to the DRAM SIMM To replace the DRAM SIMM proceed to Removing the DRAM SIMM Removing the DRAM SIMM To remove the DRAM SIMM refer to Figure B 5 and proceed as follows 1 Refer to...

Page 79: ...or until the two alignment notches and the tabs on the two connector arms lock the DRAM SIMM into place 3 Reinstall the NEM Refer to Reinstalling the Optional Network Expansion Module on page B 12 for...

Page 80: ...o the standoffs on the main PC board 2 Locate the DIMM connector on the main PC board Refer back to Figure B 2 for the DIMM location on the 4H4285 49 3 Push the connector arms away from the DIMM as sh...

Page 81: ...outward push the DIMM down between the connector arms Then release the two connector arms to lock the DIMM into place 3 Reinstall the safety cover Refer to Reinstalling the Safety Cover on page B 13...

Page 82: ...saved coverplate screws to fasten the NEM to the DFE Gold module front panel but do not tighten screws at this time 4 Insert the saved standoff through the NEM to the standoff on the main board Screw...

Page 83: ...This completes the safety cover installation Warning The safety cover protects you from exposure to an energy hazard in excess of 240 Volt Amperes Never operate the DFE module without the safety cove...

Page 84: ...1 Safety cover 2 Screws 7 3 Standoff 7 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM CPU MGMT GROUP SELECT GROUP 1 2 3 4 5 6 7 8 9 10 11 12 POE 12 X 14X 24X G R O U P 3 25X 35X 26X 36X G R...

Page 85: ...s the power supply current and the other pair provides a path for the return current While several proprietary legacy implementations of PoE have been deployed by LAN equipment vendors in 2003 the IEE...

Page 86: ...he status signals indicate the presence and operating state of each power supply module in the N POE Power System This 48 Vdc Optional Power Input interface is not fused as the N PoE Power System has...

Page 87: ...from the default RX TX Status Mode to the PoE Port Status Mode using the DFE module front panel GROUP SELECT button The switch operation and a description of how to use the LED indications are descri...

Page 88: ...PoE Port Status LEDs C 4 About PoE Power over Ethernet...

Page 89: ...B 3 E Electromagnetic Compatibility EMC requirements A 3 F Front panel UTP connections 3 13 G GROUP SELECT button use of the 4 2 4 3 I Installation connecting to the network 3 12 module into Matrix E7...

Page 90: ...Related manuals obtaining xvi Required Tools B 1 Required tools B 1 RESET button See OFFLINE RESET button S Safety Cover installation of B 13 removal to access memory B 5 Safety requirements A 3 Speci...

Reviews: