Features
1-2
Introduction
Figure 1-1
The 5C105 Chassis with Redundant Power Supplies
1.2
FEATURES
Redundant Power Supply Modules
The 5C105 supports two power supply modules which reside in the slots labeled PS1 and PS2.
Each power supply module supports an ac input connector that allows each power supply to be
connected to a separate ac power source. In addition, the power supply modules are capable of load
sharing 50% (+/- 5%) of the total load presented by the 5C105. If one of the power supply modules
fails, the other power supply module supplies the entire load for the chassis without interruption to
network traffic.
CAUTION: If the 5C105 is configured with a single power supply module it must be
located in slot PS1.