55 |
P a g e
13.
Mounting instructions
.
Table of Contents
13.1. General
13.2. Mounting of the unit
13.2.1 Brackets and gaskets to avoid vibration
13.2.2 Mounting of cooker hood
13.2.3 Duct cover
13.2.4 Dimensions and technical data
13.3. Connections
13.3.1 Electrical connections
13.3.2 Duct connections
13.4. Setting the airflow
13.5. Alarms
13.1. General
This guide is made to provide installation and user instructions regarding the correct installation of
Ensy AHU.
Ensy AHU is designed for heat recovery with air volumes from 200 m³ / h of up to 700 m³ / h. The
energy from the exhaust air is transferred to supply air through the rotary heat exchanger where the
air streams pass each other without making contact.
The unit has a built in-heater for supplementary heating of supply air. Humidity sensor for forced
ventilation is integrated into ventilation unit.
The unit can also connect additional equipment cooker hood over the stove, pulse switch for
controlling the forced ventilation, for example, wet rooms or bathrooms, sensor for carbon
management and switch management away / home function. Controls of these options are integrated
into Ensy AHU.
Ensy AHU is supplied in painted finish, tested and ready for operation. Installation, commissioning and
tuning must be performed by authorized personnel.
13.2. Mounting
Together with the unit is delivered the following equipment:
1. Suspension bracket and stoppers
2. Wall Bracket with vibration dampening gasket
3. Self-adhesive vibration damping
4. Accessories bag containing the necessary screws
5. 1 pcs. plug for connecting the cooker hood.
6. Control panel
Summary of Contents for AHU 200B
Page 1: ...User manual and Installation Guide InoVent AHU 200 700 ...
Page 2: ...393930 2 Rev 0 01 04 2020 2 P a g e ...
Page 31: ...393930 2 Rev 0 01 04 2020 31 P a g e ...
Page 41: ...393930 2 Rev 0 01 04 2020 41 P a g e ...
Page 72: ...393930 2 Rev 0 01 04 2020 72 P a g e Ensy AS Mohagasvingen 1 N 2770 JAREN http www ensy no ...