393930-2 Rev 0: 01.04.2020
66 |
P a g e
Demand controlled ventilation - adequate air quality
Humidity sensor:
Humidity sensor for
forced ventilation is
integrated into
ventilation unit.
Air handling units should be
located in suitable rooms in
central residence (utility /
laundry room) to ensure easy
access for service and filter
change.
If mounted in wet rooms or
bathroom then the contact
points must be sealed so that
it can not penetrate water.
This is especially for KV,
gaskets and USB connector.
Motion Detector:
When installed in a living
room, this will give the
signal to the unit to
increase speed to max
airflow.
CO² sensor:
Can be installed in the
living room and will give
signal to the unit if the
pollution level in the
room is too high.
Control panel:
Control panel placed at a
suitable place near the unit
to do the monitoring and
regulation of ventilation as
simple as possible. Must not
be placed in bathrooms or
wet area.
The unit is designed for
connection of external
kitchen hood.
This is an alternative
solution if there are
problems with piping
from cooker hood
through the outer wall.
Stove / Fireplace / Bathroom
Wireless control panel / pulse switch can
be used to increase supply air by use of a
stove.
Mounted in a suitable location in relation
to the unit. Can also be placed near the
bathroom for easy operation by forced
ventilation (max airflow)
Summary of Contents for AHU 200B
Page 1: ...User manual and Installation Guide InoVent AHU 200 700 ...
Page 2: ...393930 2 Rev 0 01 04 2020 2 P a g e ...
Page 31: ...393930 2 Rev 0 01 04 2020 31 P a g e ...
Page 41: ...393930 2 Rev 0 01 04 2020 41 P a g e ...
Page 72: ...393930 2 Rev 0 01 04 2020 72 P a g e Ensy AS Mohagasvingen 1 N 2770 JAREN http www ensy no ...