background image

Enphase Customer Support:

 enphase.com/en-us/support/contact

Safety and Advisory Symbols

+

DANGER

: This indicates a hazardous situation, which if not avoided, will 

result in death or serious injury.

*

WARNING

: This indicates a situation where failure to follow instructions 

may be a safety hazard or cause equipment malfunction. Use extreme 

caution and follow instructions carefully.

NOTE

: This indicates information particularly important for optimal 

system operation. Follow instructions carefully.

Safety Instructions

+

DANGER

: Risk of electric shock. Risk of fire. Do not attempt to repair the 

IQ Envoy; it contains no user-serviceable parts. Tampering with or open-

ing the IQ Envoy will void the warranty. Warranty void if cover removed. If 

the IQ Envoy fails, contact Enphase Customer Support for assistance  

(enphase.com/en-us/support/contact). 

+

DANGER: 

Risk of electrocution! Do not install CTs when current flowing 

in the sensed circuit. Always install CT wires in the terminal blocks before 

energizing the sensed circuit.

+

DANGER

: Risk of electric shock. Do not use Enphase equipment in a 

manner not specified by the manufacturer. Doing so may cause death or 

injury to persons, or damage to equipment. 

+

DANGER

: Risk of electric shock. Be aware that installation of this 

equipment includes risk of electric shock. Do not install the IQ C 

without first removing AC power from the Enphase System. Ensure the 

power coming from the microinverters is de-energized before servicing 

or installing.

+

DANGER

: Risk of electric shock. Risk of fire. Only qualified personnel 

should troubleshoot, install, or replace the IQ C.

+

DANGER

: Risk of electric shock. Improper servicing of the IQ C 

or its components may result in a risk of shock, fire or explosion. To 

reduce these risks, disconnect all wiring before attempting any mainte-

nance or cleaning.

+

DANGER

: Risk of electric shock. Always de-energize the AC branch circuit 

before servicing. While connectors are rated for disconnect under load, it 

is a best practice to de-energize before disconnecting. 

+

DANGER

: Risk of electric shock. Risk of fire. Only use electrical system 

components approved for wet locations.

+

DANGER

: Risk of electric shock. Risk of fire. Ensure that all wiring is 

correct and that none of the wires are pinched or damaged. 

+

DANGER

: Risk of electric shock. Risk of fire. Do not work alone. Someone 

should be in the range of your voice or close enough to come to your aid 

when you work with or near electrical equipment. Remove rings, brace-

lets, necklaces, watches etc. when working with batteries, photovoltaic 

modules or other electrical equipment.  

+

DANGER

: Risk of electric shock. Risk of fire. Before making any connec-

tions verify that the circuit breaker(s) are in the off position. Double check 

all wiring before applying power.  

+

DANGER

: Risk of electric shock. Risk of fire. Do not wire unused termi-

nals or terminal blocks on the IQ Envoy.

+

WARNING: 

Risk of electric shock. To maintain the warranty,  

do not modify the dead-front other than to remove filler plates, as 

needed. 

*

WARNING

: Before installing or using the IQ C, read all instruc-

tions and cautionary markings in the technical description and on the 

equipment.

*

WARNING

: Use the circuit breakers in the Enphase IQ C only for 

serving Enphase equipment. No other loads are allowed.

FCC Statement

: This equipment has been tested and found to comply with the limits 

for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency energy 

and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interfer-

ence will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the 

equipment off and on, you are encouraged to try to correct the interference by one or 

more of the following measures:

  - Reorient or relocate the receiving antenna.

  - Increase the separation between the equipment and the receiver.

  - Connect the equipment into an outlet on a circuit different from that  

     to which the receiver is connected.

  - Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compli-

ance may void the user’s authority to operate the equipment.

This Class B digital apparatus complies with Industry Canada ICES-003.

*

WARNING

: This unit is not provided with a GFDI device. This inverter or 

charge controller must be used with an external GFDI device as required by 

the Article 690 of the National Electrical Code for the installation location. 

*

WARNING

: The IQ C has a pre-installed heat shield attached to 

the enclosure door. Do not remove the heat shield.

*

WARNING

: This product is intended for operation in an environment 

having a maximum ambient temperature of 46ºC (115ºF).

NOTE

: Perform all wiring in accordance with all applicable local electrical 

codes, with the Canadian Electrical Code, Part I, and with the National 

Electrical Code (NEC), ANSI/NFPA 70.

NOTE

: Protection against lightning and resulting voltage surge must be in 

accordance with local standards. 

NOTE

: Using unapproved attachments or accessories could result in 

damage or injury.

NOTE

: Install the IQ C in the field with 75°C or higher copper 

conductors sized per local code requirements and voltage drop/rise 

considerations. 

NOTE

: Use Class 1 wiring methods for field wiring connections to terminals 

of a Class 2 circuit. Use 14 to 6 AWG wire for branch circuits and 14 to 3 

AWG for output circuits. Select the wire gauge used based on the protection 

provided by the circuit breaker(s)/fuses. Overcurrent protection must be 

installed as part of the system installation. 

NOTE

: To ensure optimal reliability and to meet warranty requirements, 

the Enphase IQ C must be installed according to the instruc-

tions in this manual.

SAFETY

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Follow these important instructions during installation and maintenance of 

the IQ C. 

Summary of Contents for IQ Combiner+

Page 1: ... that installation of the Combiner has two parts To ensure successful device detection complete Part 2 after install ing any Enphase IQ Microinverters and or Enphase AC Battery ies Note If needed you can find an installation map at the back of any Enphase Microinverter Quick Install Guide Model X IQ AM1 240 2 IQ Envoy Display and Controls Network Communications LED Green when IQ Envoy is connected...

Page 2: ... sized to meet local code requirements and voltage drop rise considerations B Bring in the wires from each AC branch circuit C Connect the ground green or green yellow to the ground busbar D Pass the L1 conductors from each PV branch circuit through the produc tion CT in the same direction as the arrow on the side of the CT E If you use the fourth Battery PV breaker position for PV you must route ...

Page 3: ...nstall consumption metering CTs DANGER Risk of electrocution Do not install CTs when cur rent is flowing in the sensed circuit Always install CT wires in the terminal blocks before energizing the sensed circuit Load Center To Grid From IQ Combiner IQ Envoy Terminal Block Relay contacts if needed UP TO 250 Vac 100A 0 5V 45 66Hz white blue Not used white blue P1 C1 C2 1 2 3 4 NO Ref Common C Digital...

Page 4: ...file settings 8 INSTALLATION Part 2 You must complete Installation Part 2 after installing any Enphase IQ Microinverters and or Enphase Battery ies Detect Devices A Turn on the DG breaker s B Use one of the following methods to detect devices Enphase IQ Microin verters and or Enphase Batteries Method A Provision devices with Installer Toolkit Use the Installer Toolkit mobile app to configure the I...

Page 5: ...Toolkit mobile app to see which devices are not com municating Check that the circuit breaker s in the IQ Combiner for the PV array are in the ON position Verify that the PV modules are connected to the microinverters Verify the PV module DC voltage is within the allowable range for the microinverter c Power production issues If the Power Production LED lights solid amber check the Installer Toolk...

Page 6: ...eded WARNING Before installing or using the IQ Combiner read all instruc tions and cautionary markings in the technical description and on the equipment WARNING Use the circuit breakers in the Enphase IQ Combiner only for serving Enphase equipment No other loads are allowed FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to par...

Reviews: