UM.02 ENOLINE WINE CARD
Page 14 of 46
Rev 08, May 2010
Bottle engagement
indicator led(s) is
(are) off.
Only some bottle
engagement
indicator leds are
on.
Bottle was engaged
while the machine was
off.
Bottle is missing.
Tap sealing is not
pushing the microswitch
behind the tap. (for off
ones)
Remove the bottle and
insert it while the machine
is on.
Engage the bottle.
Push manually upwards the
tap sealing checking the
click of the switch.
Bottle engagement
indicator led
switches off when
bottle is not empty.
Wrong operative
parameters.
Check parameter # 5 (full
bottle capacity) in
programmino mode.
Pouring is not
fluent.
Internal straw is not
properly inserted.
The filter at the bottom
of the internal straw is
stucked (especially with
sediment or aged
wines).
Tank is almost empty or
pressure is not enough.
Remove the bottle and fix it
properly.
Remove the bottle and
clean the filter.
Change the tank.
Wine drops falling
from the spouts.
Some wine sediments or
cork pieces are blocking
the dispensing valve.
Pour citric acid solution to
remove all the sediments
and foreign objects from the
valve.
Pistons fall down.
Loss or leak of pressure
on compressed
air/nitrogen supply pipe.
Check correct duty pressure
(4 Bar).
Check the pipe not to be
pressed or pricked.
Wine bubbles in the
glass while pouring.
Wine is falling on the
bottom of the glass.
Lean the glass towards the
spout.
TEMPERATURE CONTROLLED MODELS
Trouble
Origin
Solution
Set temperature is
not reached.
Not enough air
circulation.
Check the free space aside the
compressor engine (300mm)
and provide it if missing.
WINE CARD MODELS
Trouble
Origin
Solution
Machine doesn t
react when a
winecard is
inserted.
The winecard is not
properly inserted.
The winecard reader is
not activated.
Insert the winecard with the
chip facing downwards.
Activate the card reader
through Module Card.