UM.02 ENOLINE WINE CARD
Page 12 of 46
Rev 08, May 2010
7.5 Change the Temperature Set Point
(enoline temperature controlled models only)
If your enoline is a temperature controlled model it will typically be supplied
pre-programmed to:
8°C for refrigerated models (down to 7°C is possible), or
18°C for climate controlled models (between 7°C to 20°C range is
possible), or
8°C and 18°C for dual climate models.
If you wish to change these temperatures, please refer to the following
instructions.
Front Panel Description
1 - Ke y P
: This is used to access the programming parameters and to confirm
selection.
2 - Key DOWN
: This is used to decrease the values to be set and to select the
parameters. If the key is held down, the controls return to the previous
programming level until it exits the programming mode.
3 - Ke y U P
: This is used to increase the values to be set and to select the
parameters. If the key is held down, the controls return to the previous
programming level until it exits the programming mode.
The other buttons and functions are not required to change the temperature set
point.
Please settle the Enomatic Wine
Serving System in environments
with temperature range between
10°C and 30°C, and relative humidity
lower than 60%.
Programming the Temperature Set Point
Push key P , then release it and the display will
show SP 1 . (If you press the button too long it will
enter another menu; to return to the SP mode, wait
for 10 seconds).To modify the temperature value,
press UP
key to increase it or the DOWN key to decrease it. These keys
change the value one-by-one digit but if they are pressed longer than three
seconds, the value increases or decreases rapidly; after two seconds in the
same condition, the changing speed increases in order to allow the desired
value to be reached rapidly.
Adjust until the desired temperature value has been
reached. Exit by pushing key P and after 15
seconds the set temperature will be displayed.