1. General
1.1 Application
Various electric loads such as incandescant lamps, HV ha-
logen lamps and electronic transformers can be switched
and dimmed with the output of the Easyclick dimmer re-
ceiver. The receiver is operated with Easyclick transmitters
(radio signal). Before use, the transmitters must be assi-
gned to the receiver (max. 32 receivers). Every transmitter
can control an unlimited number of receivers.
Note:
Read through the operating instructions carefully
before putting the device into service.
1.2 Warranty conditions
These operating instructions are an integral part of both the
device and our terms of warranty. They must be handed
over to the user. The technical design of the appliance is
subject to change without prior notification.
PEHA
products
are manufactured and quality-checked with the latest tech-
nology according to applicable national and international
regulations. Nevertheless, if a product should exhibit a de-
fect,
PEHA
warrants to make remedy as follows (regard-
less of any claims against the dealer to which the end-user
may be entitled as a result of the sales transaction):
In the event of a justified and properly-established claim,
PEHA
shall exercise its prerogative to either repair or re-
place the defective device. Further claims or liability for
consequential damage are explicitly excluded. A justifiable
deficiency is one in which the device exhibits a structural,
manufacturing, or material defect that makes it unusable or
substantially impairs its utility at the time it is turned over to
the end-user. The warranty does not apply to natural wear,
unintended usage, incorrect connection, device tampering
or the effects of external influences. The warranty period is
for 24 months from the date of purchase by the end-user
from a dealer and ends not later than 36 months after the
device’s date of manufacture. German law shall be applica-
ble for the settlement of warranty claims.
1.3 Disposal of the device
The device must be disposed of in compliance with the laws
and standards of the country in which it is operated!
2. Safety
CAUTION! Danger of electrical shock!
The housing contains current-carrying com-
ponents. Contact can lead to personal injury!
All work on the mains network and the de-
vice may only be done by an authorised
electrician.
• Disconnect power supply from the device prior to per-
forming any work on it.
• Secure the device against being powered on again.
• Check that the device is powered off.
• Close the housing securely before applying power.
The following must be observed:
• Prevailing statutes, standards and regulations.
• State-of-the-art technology at the time of installation.
• The device’s operating instructions.
• Operating instructions can only cite general stipulations.
These are to be viewed in the context of a specific system.
This device is only intended to be used for its stated ap-
plication. Unauthorised conversions, modifications or
changes are not permissible! This device may not be used
in conjunction with other devices whose operation could
present a hazard to persons, animals or property.
3. Technical specifications
Note:
The strength of the radio signal between sender and
receiver decreases with increasing distance. The visually
unobstructed range is about 30 m in passageways and
100 m in open rooms. The range can be increased through
the use of an Easyclick repeater.
4. Installation and commissioning
4.1 Safety information
Installation and commissioning may only be done by an
authorised electrician. Mains power (230 V ~/50 Hz) to elec-
trical equipment must be switched off during installation.
Applicable laws and standards of the country in which the
device is operated must be observed!
4.2 Installation information
• NEVER install Easyclick receivers in a metal enclosure
or in the immediate vicinity of large metal objects.
• Installation close to floor level or on the floor is
not recommended.
• Not suitable for electronic transformers approved for
leadingedge dimming.
• Not suitable for inductive loads
(e.g. conventional transformers or motors).
• For permitted load types, observe the max. load rating.
4.3 Installation
The receiver ’s housing design also makes it ideally suitable
for installation in a false ceiling. This is accomplished by
using the mounting hole in the middle of the housing.
Caution!
All Easyclick transmitters to be used should be assi-
gned and programmed with the desired function prior
to final installation of this receiver in a false ceiling.
•
Install receiver in a suitable position.
•
Protect power supply line with an automatic circuit
breaker (F = max. 16 A)!
•
Install connection cables.
4.4 Commissioning
• Switch on power supply after installation.
• Program the receiver (see Point 5).
General data
Transmit frequency
868,3 MHz
Power supply
230V~ / 50 Hz
Power line
protection
Circuit breaker rated
for 16 A, maximum
Ambient temperature
- 20 to + 40°C
Storage temperature
- 40 to + 85°C
Test specifications
EN 60669-2-1
Identification
CE ; KEMA/KEUR
Protection type
IP20
Load specifications
Load types
Incandescent lamps
HV-halogen lamps
Electronic transformer
Switching capacity
60 - 210 W
Range in buildings
Masonry
20m, through 3 walls max.
Reinforced concrete
10m, through 1 wall/ceiling max.
Plasterboard/wood
30m, through 5 walls max.
Installation and operating instructions
Easyclick dimmer receiver
Plus
Art.no.:
451 FU-BEP DAB
GB
1
1
230V~/50Hz
LRN/SET
CLR/MODE
N
L
230V~50Hz
451 FU-BEP DAB
60-210W
R,C
�
F
ü
r
d
ie
se
Z
e
ic
h
n
u
n
g
b
e
a
n
sp
ru
ch
e
n
w
ir
a
lle
U
rh
e
b
e
r-
re
ch
te
,
a
u
ch
fü
r
d
e
n
F
a
ll
d
e
r
P
a
te
n
ta
n
m
e
ld
u
n
g
o
d
e
r
G
e
-
b
ra
u
ch
sm
u
st
e
re
in
tr
a
g
u
n
g
.
V
e
rv
ie
lf
ä
lt
ig
u
n
g
o
d
e
r
W
e
it
e
r-
g
a
b
e
a
n
D
ri
tt
e
n
u
rn
a
ch
u
n
se
re
rv
o
rh
e
ri
g
e
n
Z
u
st
im
m
u
n
g
.
Infratec
Datentechnik GmbH
D a t u m
N o r m
Ä n d e r u n g
Name
Dateiname:
Blatt
Bl.
Urspr.:
Format DIN A4H
Datum
Zust.
G e p r.
Bearb.
N a m e
230V/50Hz~
L
N
F
N L
Learn mode:
LED = red
Function programming:
LED = green or orange
L = Black
N = Blue
= Brown
LRN / SET button with LED
Learn mode and function prog.
CLR / MODE button with LED
Delete all transmitters and
parameter setting
5. Programming
For programming, the receivers must be connected to the
mains power supply. The programming is retained even in
a power failure.
5.1 Learn mode (assigning or deleting transmitters)
Notes
:
– No transmitter is assigned to the receiver
in its delivered state.
– Several transmitters can be assigned or deleted
(max. 32 receivers) in learn mode.
– A transmitter is alternately assigned (LED on) or deleted
(LED off) each time the button is pressed!
– The receiver‘s Function 1 is preset after assigning a
transmitter to the receiver. The function can be changed
for every transmitter (see point 5.3).
– If no action takes place, learn mode will be terminated
after 30 s.
5.2 Deleting all assigned transmitters
5.3 Function programming
Note:
If no action takes place, function programming will
be terminated after 30 s.
LRN/SET button
press briefly
Idle state
(LED off)
CLR/MODE button
long activation
All transmitters deleted
Learn mode (LED blinks red)
s. Point 5.1
LRN/SET button
long activation
Function programming
(LEDs blinks green rapidly)
Function setting
(LED blinks orange
number of blinks = function)
Press LRN/SET button
(number = function selection)
Transmitter detection
(Activate transmitter once)
CLR/MODE button
press briefly
Parameter setting
(LED blinks green
number of blinks = parameter)
Press LRN/SET button
(number = parameter selection)
CLR/MODE
button
press briefly
Idle state
(LED off)
Transmitter detection
(e.g. press transmitter button)
Activate transmitter once
LED blinks orange
transmitter detected
Function setting
(e.g. function 3)
LRN/SET button 3 x activated
LED blinks 3 x orange
function 3
Parameter
setting
(e.g. parameter 2)
LRN/SET button
2
x activated
LED blinks 2 x green
parameter 2
Activate transmitter once
(e.g. press button)
Transmitter assigned
(LED 1 on)
Receiver =
Function 1
Transmitter deleted
(LED off)
LRN/SET button
press briefly
Idle state
(LED off)
LRN/SET button
press briefly
Learn mode
(LED blinks red)
ELEKTROPLANET AG
IHR P
AR
TNER FÜR DIE ELEKTROBRANCHE
INDUSTRIESTRASSE 2
CH - 8
33
5
HITTNAU
+41 (0) 44 950 10 10
+41 (0) 44 950 10 44
WWW
.ELEKTROPLANET
.CH
INFO@ELEKTROPLANET
.CH