ENIGMA XM88422 Digital Receiver
Version 1.50
8
Clock signal protocol is disabled, reports the
events to COM1 without time and date
External acknowledge is disabled
Tamper recognition is disabled
The signals will be displayed on the LCD of the Line
Cards as they are received. After the Line Card
acknowledged the event to the control panel, the
event will be displayed on the LCD screen of the
CPM Unit with time and date. Events coming in
Contact ID and SIA format are automatically decoded
from the predefined event libraries. For other formats,
only the incoming code will be displayed. The events
will be reported to the computer via the serial port
COM1 and printed, if the computer is absent.
If the computer is not connected, pushing the
ENTER/ACK button will silence the buzzer. The
manual acknowledgement is recorded with time and
date.
Return to the default programming
You can return to default programming at any time by
entering the menu and selecting the ‘Factory
Defaults’ menu point from the ‘Utils’ menu.
If by any means you forget the password, then it is
not possible to enter the menu any more. In this
case, the following procedure can be done to restore
default settings:
1. Turn off the receiver
2.
Dismount the CPM module. (see ‘Removing
and Installing Modules, p. 11)
3. Open the bottom cover of the module
4. Take out the data EPROM from the memory
card. Do not mount the cover back this time.
5. Remount the CPM module
6. Turn the receiver on and wait a few seconds.
7. Turn it back off again
8. Dismount the CPM module
9. Replace the data EPROM and close cover.
10. Remount the CPM module
11. Turn on the receiver
– the receiver will start
up with the factory defaults.
Summary of Contents for XM88422
Page 1: ...User Manual ...