ENIGMA XM88422 Digital Receiver
Version 1.50
15
Note, that incoming events have priority over
browsing,
so
that
an
event
reception
will
automatically interrupt review mode, and return to the
bottom of the list, with the newly received event
highlighted in the last line.
Change List Font Size
Pressing the Shift button will change between normal
and extended display font sizes. The change is
instant; the list of events and the status row will be
displayed in the selected font size.
Note, that after changing font size the list of events
will only display the last event received. Reviewing
previous events is possible through browsing the list
of events with the Up and Down buttons.
Receiver Status Information
The receiver status can be displayed by pressing the
Info button. A dialog box will appear with essential
information:
1234567890ABCDEF0
Line Cards: ooooooooooooooooo
oooooooooooooooo
Receiver: NORMAL OPERATION
Power Status: POWER OK
COM1 Status: ABSENT
Printer: ONLINE (BACKUP)
Memory Info: 0014/0014/0000
The upper part of the dialog box shows the Line Card
registration and status. The small boxes correspond
the Line Cards in the system by the Line Card
numbers. An empty box means, that no Line Card
detected at the given Line Card number. A filled box
means that the Line Card is detected, and the
connection via the internal communications bus is in
order. A crossed box means, that the Line Card was
detected, but the connection is broken
– the Line
Card is broke down, or the Line Card Module was
pulled out.
Below that, the operating mode of the CPM Unit is
displayed. It should display “Normal Operation”. Next,
the status of the power supply, the status of the
RS232 serial port COM1 is displayed, and the status
and operating mode of the printer.
In the bottom line of the dialog box, the status of the
memory buffer is displayed. The numbers displayed
represent the event, the reporting and the printing
pointers of the memory.
Pressing the Enter or Clr buttons will return to the list
of events. If no key is pressed for one minute, the
dialog box will disappear automatically.
Protected Mode Operation
In protected mode, the receiver is operating the same
way as in normal mode, except that the menu and
local programming functions are accessible. A small
key displayed in the status row indicates protected
mode operation.
Note that not all the CPM parameters can be
programmed locally. Some of the parameters can
only be programmed by the user with the ENIGMA
Programmer Software via the serial ports, and some
of the parameters can only be changed by the
recommendation of an ENIGMA.
IMPORTANT:
The menu and the local programming
functions have priority over the incoming events to
ensure problem free local programming of the
receiver. This also means, that the received events
will not be displayed and so the operator will not be
notified if the menu or dialog boxes are active. To
avoid unnecessary delay in processing received
events enter this mode only if necessary, and leave
the menu immediately after programming. For this
reason remote programming of the receiver is
suggested instead of local programming.
NOTE:
If entered in protected mode and the menu
and local programming is not started in 30 seconds,
the receiver will automatically return to normal
operation
Entering Protected Mode
Entering protected mode is possible by pressing the
Func button and entering the proper password. Since
no numeric keypad is provided on the CPM Unit, to
enter the password, the buttons on the front panel of
the CPM Module can be used. The keys correspond
to the following values:
Right
1
Left
2
Down
3
Up
4
Info
5
Menu
6
Func
7
Shift
A
Enter/Ack
End password
Clr
Quit
The factory default password is 1234 (Right-Left-
Down-Up).