background image

ENFORCER Delayed Egress Timer 

 

12

 

                                                        

SECO-LARM U.S.A., Inc.

 

 

 

 

 

 

 

 

 

 

 

 

NOTICE  

The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy 

is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. 
SECO-LARM is also not responsible for misprints or typographical errors. 

 

Copyright © 2012 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without 
the written permission of SECO-LARM. 

WARRANTY

  This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a 

period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or 
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused 

by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty 
installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other 
than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to 
replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or 
consequential personal or property damages of any kind to the purchaser or anyone else. 
 

Order Part #763-021-3%

 

MiSA-025EQZZ_1210.docx

 

PITSW1

 

SECO-LARM

  

U.S.A., Inc

16842 Millikan Avenue, Irvine, CA 92606 

 

 

  

Website: www.seco-larm.com

 

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326  

 

  

E-mail: [email protected]

 

 

IMPORTANT

  Users and installers of this product are responsible for ensuring this product complies with all national, state, and local laws, 

statutes, and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of 
any current laws, statutes, or codes. 

Troubleshooting: 

Initiate device (such as a push-to-exit bar) 
will not release the lock 

 

Check the nuisance delay. 
See pg. 6, 

Nuisance Delay.

 

 

Check the pre-delay timer. 

See pg. 6, 

Adjusting the Pre-Delay and 

Post-Delay. 

 

Check the security mode. 

See pg. 7, 

Security Mode Jumper.

 

 

 

Door will not relock 

 

Check the relock mode. 

See pg. 5, 

Relock Modes.

 

 

Check the bypass input. 

See pg. 8, 

Bypass Input. 

 

Door automatically relocks in BOCA mode. 

 

Check the lock status. 

See pg. 7, 

Lock Status Jumper.

 

 

Also Available from SECO-LARM: 

Electromagnetic 

Locks 

 

Magnetic 
Contacts 

 

Spring-Loaded 

Switches 

 

LED Strobe  

Lights 

 

 

1-sec to 365-day 

Timers 

Made in Taiwan 

Summary of Contents for ENFORCER SA-025EQ

Page 1: ...lay outputs for lock relay and remote alarm Transistor ground output for local alarm outputs Auto or programmed relocking after power loss IMPORTANT Users and installers of this product are responsibl...

Page 2: ...put Form C 10A 24VDC Local alarm output transistor ground 500mA 12VDC Door status input Status LEDs show relay status Bypass input immediately releases locks Free egress input allows easy egress durin...

Page 3: ...er see pg 6 Post delay timer potentiometer see pg 6 Terminal block see pg 4 LED 1 Blue If ON the SA 025EQ is being powered see pg 9 LED 2 Red If ON the lock relay is energized see pg 8 LED 3 Red If ON...

Page 4: ...holes located on the side of the unit to a mounting surface Normally energized Screen print refers to energized state as normal Remote alarm relay output 10A 24VDC Form C Relay NO NC COM see pg 8 Loc...

Page 5: ...relocked by a reset device connected to the Reset Input For information on connecting a reset device see pg 4 Wiring Diagram This reset device is often a momentary spring loaded key switch BOCA Mode T...

Page 6: ...h at the bottom right of the circuit board Power Up Mode DIP Switch 1 There are two types of power up modes These modes determine the relocking status in case of a power loss Programmed Relock DIP Swi...

Page 7: ...al alarm pulses during the pre delay gradually pulsing faster until the end of the pre delay time The local alarm will continue signaling steady 5 seconds after the lock has been released When set OFF...

Page 8: ...e pg 7 LED 4 red is on when the local alarm output is active Lock Relay Output The SA 025EQ is equipped with a 10A 24VDC Form C dry relay output that can be used with a fail safe or fail secure lock T...

Page 9: ...e bypass input is used to bypass the SA 025EQ and allow unrestricted entry and exit via the door When the bypass input is activated the lock will immediately release It will remain released until the...

Page 10: ...ted to the reset input This device will manually reset the lock 4 A spring loaded switch is connected to the pre delay bypass input This will allow any authorized user immediate access to the protecte...

Page 11: ...mon terminal is connected to a positive voltage and the normally closed terminal is connected to the SA 025EQ s initiate input 3 An audible indicator sounds during the pre delay time to alert the user...

Page 12: ...rkmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any speci...

Reviews: