ENFORCER Delayed Egress Timer 

 

2

 

                                                        

SECO-LARM U.S.A., Inc.

 

 

 

Remote Alarm Relay Output ......................... 

     

Lock Relay Output ........................................ 8 
Local Alarm Output ....................................... 8 
Pre-Delay Bypass Input ................................ 8 
Free Egress Input ......................................... 9 
Reset Input .................................................... 9 
Initiate Input .................................................. 9 
Bypass Input ................................................. 9 
Lock Status Input .......................................... 9 
Power Input ................................................... 9 
Sample Applications .............................. 10-11 
Troubleshooting .......................................... 12 
Warranty ..................................................... 12 

 

3 Relock modes to meet different installation requirements: 

 

Standard manual relocking. 

 

BOCA (Building Officials Code Administrators) relocking. 

 

Timed relocking (1~60 seconds). 

 

Programmable nuisance delay timer (0~3 seconds). 

 

Adjustable pre-delay timer (1~30 seconds). 

 

Adjustable post-delay timer (1~60 seconds). 

 

Selectable manual or automatic relocking after power loss. 

 

Lock relay output (Form C, 10A@24VDC). 

 

Remote alarm relay output (Form C, 10A@24VDC). 

 

Local alarm output (transistor ground, 500mA@12VDC). 

 

Door status input. 

 

Status LEDs show relay status. 

 

Bypass input immediately releases locks. 

 

Free egress input allows easy egress during the day. 

Features: 

Specifications: 

Table of Contents: 

Operating voltage 

12~24 VAC/VDC 

Current draw 

Standby

1

 

120mA@12VDC 

Pre-delay 

90mA@12VDC 

Local alarm 

35mA@12VDC 

Timer module only

15mA@12VDC 

Lock control output  

10A@24VDC, Form C, NO/NC/COM 

Remote alarm output 

10A@24VDC, Form C, NO/NC/COM 

Local alarm output 

Transistor ground, 500mA@12VDC  

 

Features ........................................................ 2 
Specifications ................................................ 2 
Dimensions.................................................... 3 
Overview ....................................................... 3 
Installation ..................................................... 4 
Wiring Diagram.............................................. 4 
Relock Modes................................................ 5 
Adjusting the Pre-Delay and Post-Delay ....... 6 
Setting the Power-Up Mode and 

 

 

Nuisance Delay ............................................. 6 
Lock Status Jumper....................................... 7  
Security Mode Jumper .................................. 7 
Local Alarm Output Type Jumper.................. 7 
 

1

Lock relay and remote alarm relay are normally energized.  

2

When lock relay and remote alarm relay are de-energized. 

Summary of Contents for ENFORCER SA-025EQ

Page 1: ...lay outputs for lock relay and remote alarm Transistor ground output for local alarm outputs Auto or programmed relocking after power loss IMPORTANT Users and installers of this product are responsibl...

Page 2: ...put Form C 10A 24VDC Local alarm output transistor ground 500mA 12VDC Door status input Status LEDs show relay status Bypass input immediately releases locks Free egress input allows easy egress durin...

Page 3: ...er see pg 6 Post delay timer potentiometer see pg 6 Terminal block see pg 4 LED 1 Blue If ON the SA 025EQ is being powered see pg 9 LED 2 Red If ON the lock relay is energized see pg 8 LED 3 Red If ON...

Page 4: ...holes located on the side of the unit to a mounting surface Normally energized Screen print refers to energized state as normal Remote alarm relay output 10A 24VDC Form C Relay NO NC COM see pg 8 Loc...

Page 5: ...relocked by a reset device connected to the Reset Input For information on connecting a reset device see pg 4 Wiring Diagram This reset device is often a momentary spring loaded key switch BOCA Mode T...

Page 6: ...h at the bottom right of the circuit board Power Up Mode DIP Switch 1 There are two types of power up modes These modes determine the relocking status in case of a power loss Programmed Relock DIP Swi...

Page 7: ...al alarm pulses during the pre delay gradually pulsing faster until the end of the pre delay time The local alarm will continue signaling steady 5 seconds after the lock has been released When set OFF...

Page 8: ...e pg 7 LED 4 red is on when the local alarm output is active Lock Relay Output The SA 025EQ is equipped with a 10A 24VDC Form C dry relay output that can be used with a fail safe or fail secure lock T...

Page 9: ...e bypass input is used to bypass the SA 025EQ and allow unrestricted entry and exit via the door When the bypass input is activated the lock will immediately release It will remain released until the...

Page 10: ...ted to the reset input This device will manually reset the lock 4 A spring loaded switch is connected to the pre delay bypass input This will allow any authorized user immediate access to the protecte...

Page 11: ...mon terminal is connected to a positive voltage and the normally closed terminal is connected to the SA 025EQ s initiate input 3 An audible indicator sounds during the pre delay time to alert the user...

Page 12: ...rkmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any speci...

Reviews: