ENFORCER Delayed Egress Timer
2
SECO-LARM U.S.A., Inc.
Remote Alarm Relay Output .........................
8
Lock Relay Output ........................................ 8
Local Alarm Output ....................................... 8
Pre-Delay Bypass Input ................................ 8
Free Egress Input ......................................... 9
Reset Input .................................................... 9
Initiate Input .................................................. 9
Bypass Input ................................................. 9
Lock Status Input .......................................... 9
Power Input ................................................... 9
Sample Applications .............................. 10-11
Troubleshooting .......................................... 12
Warranty ..................................................... 12
3 Relock modes to meet different installation requirements:
Standard manual relocking.
BOCA (Building Officials Code Administrators) relocking.
Timed relocking (1~60 seconds).
Programmable nuisance delay timer (0~3 seconds).
Adjustable pre-delay timer (1~30 seconds).
Adjustable post-delay timer (1~60 seconds).
Selectable manual or automatic relocking after power loss.
Lock relay output (Form C, 10A@24VDC).
Remote alarm relay output (Form C, 10A@24VDC).
Local alarm output (transistor ground, 500mA@12VDC).
Door status input.
Status LEDs show relay status.
Bypass input immediately releases locks.
Free egress input allows easy egress during the day.
Features:
Specifications:
Table of Contents:
Operating voltage
12~24 VAC/VDC
Current draw
Standby
1
120mA@12VDC
Pre-delay
90mA@12VDC
Local alarm
35mA@12VDC
Timer module only
2
15mA@12VDC
Lock control output
10A@24VDC, Form C, NO/NC/COM
Remote alarm output
10A@24VDC, Form C, NO/NC/COM
Local alarm output
Transistor ground, 500mA@12VDC
Features ........................................................ 2
Specifications ................................................ 2
Dimensions.................................................... 3
Overview ....................................................... 3
Installation ..................................................... 4
Wiring Diagram.............................................. 4
Relock Modes................................................ 5
Adjusting the Pre-Delay and Post-Delay ....... 6
Setting the Power-Up Mode and
Nuisance Delay ............................................. 6
Lock Status Jumper....................................... 7
Security Mode Jumper .................................. 7
Local Alarm Output Type Jumper.................. 7
1
Lock relay and remote alarm relay are normally energized.
2
When lock relay and remote alarm relay are de-energized.