background image

42E724P Programmable In-Wall Timer 
Installation and Operating Instructions 

 

Use as replacement for standard indoor wall box toggle switch to provide automatic control of outdoor or indoor lighting, fans, 
pumps, office machines, and other types of circuits rated at 120 VAC.  

 

Installation Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Operation Instructions 

 

Power Up Sequence: 

 
 
 
 

 

Setting Current Time:

 

 Press and HOLD the “CLOCK” key during this procedure. 

 
 
 
 
 
 
 
 

 

Programming “ON/OFF” Events: 

 
 
 
 

 
 

 
 

This device requires installation by a licensed electrician or qualified professional. Use 
of voltage detector or meter is recommended.  

(Wiring diagram provided for reference.)

 

1.  Turn OFF the main power 
2.  Remove the existing switch. 
3.  Connect the wires of Timer and wall box as followed by using the wire nuts 

provided.  
a.  Connect the Hot/Live wire of main power to the Black wire from Timer. 
b.  Connect both the Neutral wires of main power and load to the White wire 

from Timer. 

c. 

Connect the Hot/Live wire of Load to the Red wire from Timer. 

d.  Connect the Earth (Ground) wire to the Yellow/Green wire from Timer.   

 

Note:  Be sure that all the wire nuts are secure. 

 

4.  Tuck the wires into the wall box leaving room for the Timer. 
5.  Using the screws provided, place through the Big hole on the mounting yoke of 

Timer to mount the Timer to the wall box.

 

Block Programming:  

When programming “ON/OFF” events, 

all days are indicated by default. To change the day 
selection; simply keep pressing the “Day” key and the display 
will change as follows: Individual Day (MON, TUE, etc.); 
MON~FRI; SAT~SUN; MON~SAT; MON~SUN; MON-WED-
FRI; TUE-THU-SAT; MON-WED; THU-SAT.  Follow the 
steps above to complete programming. 

 

Reviewing Programs:  

To review entered programs; simply 

press and release the “PROG” key. Each time you do this 
you will be able to scroll thru the programs. Any program can 
be edited simply by pressing the HOUR, MIN, and DAY keys. 
Then press the PROG key in order to accept the changes.
When complete press the “CLOCK” key to return to current 
time and day. 

 

MEMORY BACKUP:  

The 42E724P is equipped with a 

rechargeable Ni-Mh battery which will protect your programs 
during power failure for up to 30 days. No need to replace 
battery. Note that the screen blanks during a power failure.

 

Deleting Programs:  

To delete a particular program press the 

PROG key until the desired program is displayed. Then press 
the HOUR and MIN keys until 

--:--

 

is displayed. Then 

press the PROG key in order to delete the program.  When 
complete press the “Clock” key to return to current time and 
day. Manual Override: Pressing the 42E724P cover while 
closed will alternate the unit ON or OFF. 

 

Disable Function:  

The 42E724P has a disable function 

whereby the programs do not execute. It’s ideal during 
Holidays of vacation period where the unit is not to perform 
any function. Simply slide bottom slide switch of OFF. 

 

Initial Startup:  

When you initially program the unit it may be 

necessary to press the manual override key as the unit will 
not look back to determine if it should be ON. Example: the 
current time is 2:00PM and you just programmed the unit to 
turn “ON” at 1:00PM, press the manual override key to turn
the unit “ON”. Thereafter, the unit will resume normal
automatic operation.

 

NOTE:  In the event that the screen is blank, check the following: 

1. The OFF/TIMER switch located at the bottom may be in the OFF 

position. Slide it to the TIMER position using a small screwdriver. 

2. Check LOAD connected to the 42E724P. 
3. Check the 120VAC power source.

 

NOTE: It is necessary to press “MIN” at least 
once to display “OO” for minutes (ex. 9:00 AM).  
By default all days are indicated. 

1.  Press the “PROG” key once. TIMER 1 ON 

--:--

appears.  Using the 

“HOUR” and “MIN” keys enter the desired ON time. When complete press the 
PROG key once.   

2. Timer 

OFF 

--:--

 

will be displayed. Using the “HOUR” and “MIN” keys enter 

the desired OFF time. When complete press the PROG key once. 

3.  If complete press the “CLOCK” key to return to current time and day.  A total of 

7-ON and 7-OFF events can be programmed.   

4.

Close door when programming completed.

1.  Press the “HOUR” key to advance the hours.  
2.  Press the “MIN” key to advance the minutes. 
3.  Press the “DAY” key to advance the day. 
4.  If any keys are pressed for a prolonged period, the display will advance rapidly. 
5.  Release the “CLOCK” key once the time and day have been entered.  

 

The timer is operating and ready to program. The colon “

:

” after the hours will 

continuously flash indicating that the time is advancing.  

1.  Lift up the bottom of the door using a small slotted screwdriver. 
2.  Position the slide switch to TIMER. 
3.  Press the "RESET" button using a paper clip. 
4.  The display should flash 12:00AM on Monday.

  

SPECIFICATIONS: 

Ratings: 

120VAC, 60Hz      1HP 
15A Resistive        15A Tungsten

Wire in accordance with National and Local Electrical Codes. 

 