LCD METER
USER MANUEL
4
5.
In display 3, hold the button
(SW)
shortly to enter display 1.
6. In each display interface, if you hold the button (SW), the meter and the controller will turn off.
7. Automatic Prompt Interface
7.1 Error code display
When the electronic control system of the electric vehicle fails, the meter will automatically display (flicker) a fault code.
You can’t exit the fault code display until the problem is solved.
7.2 Motor operating temperature alarm
When the motor operating temperature exceeds the warning value, the display will flash to warn you. The controller will offer the appropriate protection to the motor.
GENERAL SETTINGS
1. Maximum Trip Speed
Hold the button
(SW)
to turn the meter on. After 5 seconds hold the button (UP) and the button
(DOWN)
simultaneously for about 2 seconds.
The speed display column will then flash. Hold the button shortly
(UP)
or the button
(DOWN)
to set the maximum riding speed.
The default maximum riding speed is 25 km/h. Once you have finished, hold the button shortly
(SW)
to save the current values and enter the next setting.
Distribué par
|
Distributed by:
TCED INTL. Inc.
700, chemin du Grand Bernier Nord
Saint-Jean-sur-Richelieu
(Québec) J2W 2H1
Toll free/Sans frais: 1 800-661-3330
3. Display 2
Hold the button
(SW)
shortly to enter display 2.
After riding for 5 seconds, display 1 will automatically appear.
In display 1, the original motor power is replaced by the motor running temperature as shown in the image.
4. Display 3
Hold the button
(SW)
shortly to enter display 3.
After cycling for 5 seconds, the single maximum speed will automatically return to the real-time trip speed (km/h)
as shown in the image.
2. Wheel Diameter
Hold the button
(UP)
or the button
(DOWN)
to choose the necessary wheel diameter specifications.
There are 13 different diameters: 6,8,10,12,14,16,18,20,22,24,26,700 c and 28 inches. Hold the button
(SW)
shortly to save
your changes and enter the next setting.
3. Metric and Imperial Units
Hold the button
(UP)
or the button
(DOWN)
shortly to set the three different
metric/imperial units: speed, mileage and external temperature.
4.
Hold the button shortly (SW) to save your changes.
The speed and mileage units will then stop flashing. If you hold the
button
(SW)
shortly again, the maximum riding speed display
will appear. Alternatively, hold the button
(SW)
for about
2 seconds to exit the general settings interface and return to display 1.
5. Exit General Settings
Hold the button
(SW)
for about 2 seconds to exit any one of the three general settings and return to display 1. The current settings will be saved.
If the meter isn’t used for more than 1 minute, it will automatically return to display 1, and the original settings will be saved.
Error Code
Definition
01 info
Throttle abnormality
03 info
Motor hall signal abnormality
04 info
Torque sensor signal abnormality
Display
Metric
Imperial
Riding speed
Km/H
MPH
Total distance
Km
Mil
Environment temperature ºC temperature ºF temperature
Error Code
Definition
05 info
Axis speed sensor abnormality (only applies to torque sensor)
06 info