6
MODEL: EWC12-148
USER’S MANUAL
THE CHARGING PROCESS
(CONTINUED)
SMART CHARGING MODE
•
Analysis Mode ( Battery retention test Mode)
ƒ The charging is interrupted for a short period for battery voltage measured
ƒ If the battery voltage falls too quickly, the battery is probably faulty.
ƒ The green full charging LED is flash
•
Float Mode (Safe voltage level of 13.2V)
ƒ Full Green LED is ON.
ƒ The Float Mode allows the charger to effectively be left connected to your batteries; it works at a safe level of 13.2V,
and the battery is ready for use.
•
Maintenance mode (Special pulse for long term maintenance)
ƒ Full Green LED is ON.
ƒ The program engages a special charging waveform and monitors the battery voltage variations, if the battery voltage sinks,
the special pulses will keep the battery in optimal state, if the battery voltage drops even lower, the battery charger will switch
into Bulk charging stage. The maintenance mode allows the charger can be connected to the battery over the course of a
season; if possible; check the electrolyte liquid level in the battery.
STEP 4 - DISCONNECTING THE BATTERY CHARGER FROM BATTERY
• If the Battery is out of the vehicle.
- Switch OFF and Remove the AC Power Socket from the outlet.
- Remove the Black lead and then the Red lead.
- Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
• If the Battery is in the vehicle.
- Switch OFF and Remove the AC Power Socket from the outlet.
- Remove the lead from the vehicle chassis.
- Remove the lead from the battery.
- Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
LED STATUS INIDICATOR TABLE
Fault/Erreur
Full/Pleine
Pure Lead
Plomb pur
GEL
AGM & Wet
AGM et Humide
Absorption
Regular
/Régulier
Maintenance
/Entretien
Charge Mode
Type de charge
Battery Type
Type de batterie
Bulk/Masse
1A
Smart Charger
Chargeur intelligent
4A
Maximum
8A
1
2
3
4
5
6
7
8
9
10
11
12