THE CHARGING PROCESS 

The charging stages and performance are as follows:

ECO Mode

If ac power is connected, and the battery is not connected, after 10 seconds, the charger will automatically go into ECO mode.

• The Green LED is fast flashing indicates the ECO mode.

BATTERY INITIAL QUALIFICATION

When the battery is connected and ac powers on, the program will automatically run qualification as the following processes:

- Detects the battery internal impendence and initial voltage.

- Determine the charging rate acceptance.

- Diagnoses the battery sulphated condition.

ENHANCED BATTERY REJUVENATION

If the initial qualification detected that the battery was in poor condition, our unique rejuvenation process 

(patented in USA and Europe) will begin automatically. During the rejuvenation process, a high voltage equalizing and 

peak pulse reconditioning charge is used to repair the sulphated battery, this unique patented feature will break down and 

dissolve the lead-sulphate crystal built up on the battery plates, balance out the high concentrations of acid, which is to extend 

your battery life and performance.

If the battery voltage does not reach 9V within 24 hours, the Rejuvenation process will be timed out.

• The Blue LED is flashing indicates the Rejuvenation stage.

If the program detects the battery can be normally accepted charging current, it will directly go into Soft start stage; 

if the battery still can not accept the charging current after 24 hours rejuvenation, it expresses the Battery Rejuvenation 

fails and the battery is not healthy.

• The Red LED will be ON to indicate the battery rejuvenation failure.

SMART CHARGING MODE

There are following stages:
• 

Soft start Charging Mode (C.C. Mode)

  ƒ Blue Charging LED is flashing.

  ƒ Gently ramps up the battery voltage to 11V, if the battery voltage doesn’t reach 11V within 6 hours, 

      the charger will engage a safety timer protection and RED faulty LED will start flash.
• 

Bulk Charging Mode (C.C. Mode)

  ƒ Blue Charging LED is ON.

  ƒ The battery can be charged about 80%.

  ƒ The charger delivers an almost constant current of the maximum output until the battery voltage reaches 

     the preset voltage value within 24 hours, if the battery voltage doesn’t reach preset voltage value within 24 hours, 

     the charger will engage a safety timer protection and RED faulty LED will start flash.
• 

Absorption Mode (C.V Mode)

  ƒ Green absorption charging LED is ON.

  ƒ The battery can charge up to almost 100%.

  ƒ The charging current tapers and the charging voltage are kept constant at the preset value without overcharging.
• 

Equalization charging

  ƒ Blue Bulk LED and Green Equalization LED both flashing.

  ƒ A well proven process that carefully equalize the battery to store it’s full capacity, the Equalization stage for Pure Lead 

     battery selection is automatic. The equalization stage for AGM & WET and GEL battery only occurs if the in Initial start 

     voltage is below 11 Volts.

Summary of Contents for EWC12-148

Page 1: ...e immediately with water if acid comes into contact with skin or eyes The charger should be used on a flat surface Never charge a frozen battery Never charge a damaged battery Never place the charger on the battery while charging Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion When work...

Page 2: ...s Corrosion resistant output connectors Output clips and ring terminals provided It comes with a quick connect fly lead and 2 different kinds of connectors crocodile clips and a ring terminals The ring terminals are perfect for permanent connection to your battery You can connect the lead to the battery and tuck the lead away while you are using your vehicle and when you get back to your garage si...

Page 3: ...ies may be able to handle a higher Charge Current Check with the battery Manufacturer when charging batteries with small capacity ELECTRICAL PARTS Delivered with A C Power Cord 6 feet with UL Plug Output Lead 4 feet with Trailer Connector Extension Cord 2 feet with Trailer Connector Battery Clamp or 2 feet with Trailer Connector Ring Connector ENVIRONMENTAL CHARACTERISTICS Operating Temperature 0 ...

Page 4: ...and then connect the Black battery charger lead to the vehicle s chassis and away from the fuel line If Positively grounded FIRST Connect the Black battery charger lead to the Negative battery post and then connect the Red battery charger lead to the Vehicle s chassis and far away from the fuel line STEP 3 CONNECT THE BATTERY CHARGER TO MAINS POWER Connect the battery charger to the Mains Powered ...

Page 5: ...ing current it will directly go into Soft start stage if the battery still can not accept the charging current after 24 hours rejuvenation it expresses the Battery Rejuvenation fails and the battery is not healthy The Red LED will be ON to indicate the battery rejuvenation failure SMART CHARGING MODE There are following stages Soft start Charging Mode C C Mode ƒ Blue Charging LED is flashing ƒ Gen...

Page 6: ...will switch into Bulk charging stage The maintenance mode allows the charger can be connected to the battery over the course of a season if possible check the electrolyte liquid level in the battery STEP 4 DISCONNECTING THE BATTERY CHARGER FROM BATTERY If the Battery is out of the vehicle Switch OFF and Remove the AC Power Socket from the outlet Remove the Black lead and then the Red lead Check el...

Page 7: ...er temperature protection mode Soft start charging timed out if Blue bulk LED also flashing fast Bulk charging LED timed out if Blue Bulk LED also ON LED STATUS DESCRIPTIONS CHARGING CURVE Fast Flash Rejuvenation Slow Flash Soft start charging ON Bulk charging 7 Green Flashing ON Flashing indicates Equalization charge or ON indicates Absorption charging 8 Green Flashing ON Flashing if Analysis fai...

Page 8: ...has no DC output Fault RED LED is ON Output is short circuited Reverse polarity connection to Battery Check DC connection between charger and battery and make sure they are not short circuiting Check that the crocodile clips haven t fallen off the battery Check that the crocodile clips ring terminals are connected to the correct polarity No Charging Current Fault RED LED is Flashing Battery is sev...

Page 9: ...ions L acide de batterie est corrosif Si l acide vient en contact avec la peau ou les yeux rincer immédiatement avec de l eau Le chargeur doit être utilisé sur une surface plane Ne jamais charger une batterie gelée Ne jamais charger une batterie endommagée Ne jamais placer le chargeur sur la batterie durant le processus de chargement Faire preuve d extrême prudence afin de réduire le risque de lai...

Page 10: ...re la surcharge de batterie Câbles robustes Connecteurs de sortie résistant à la corrosion Pinces et cosses annulaires fournies L ensemble comprend un câble principal à connexion rapide avec deux câbles de chargement dotés d extrémités différentes pinces crocodiles et cosses annulaires Les cosses annulaires sont idéales pour une installation permanente sur une batterie On peut laisser le câble de ...

Page 11: ...plomb À gel à l électrolyte humide AGM au plomb pur Taux de charge réglable Batterie de 12 V Certaines batteries ne peuvent pas supporter une intensité de charge élevée vérifier auprès du fabricant de la batterie si la capacité de la batterie n est pas élevée ÉLÉMENTS ÉLECTRIQUES Le chargeur est fourni avec les éléments suivants Cordon d alimentation électrique c a 6 pieds 1 8 m avec fiche UL Câbl...

Page 12: ...cule loin de la conduite de carburant Mise à la masse positive COMMENCER par connecter le câble noir du chargeur à la borne de batterie négative puis connecter le câble de charge rouge au châssis du véhicule loin de la conduite de carburant ÉTAPE 3 BRANCHER LE CHARGEUR DE BATTERIE SUR L ALIMENTATION ÉLECTRIQUE Brancher le chargeur de batterie sur la prise d alimentation électrique Le chargeur déma...

Page 13: ...rogramme détermine que la batterie peut normalement tolérer le courant de charge il passe directement à la phase de démarrage lent si la batterie ne peut toujours pas tolérer le courant de charge après 24 heures de reconditionnement le programme indique que la phase de reconditionnement a échoué et que la batterie n est pas en bon état Le voyant à DEL rouge Fault Erreur s allume pour indiquer un é...

Page 14: ... Si la tension descend davantage le programme passe à la phase de charge principale Le mode de maintien permet de laisser le chargeur connecté à la batterie durant une saison entière si possible vérifier le niveau de l électrolyte dans la batterie ÉTAPE 4 DÉCONNECTER LE CHARGEUR DE LA BATTERIE Si la batterie est hors du véhicule Mettre le chargeur hors tension et le débrancher de la prise de coura...

Page 15: ...t DEL bleu de charge intensive clignote rapidement également interruption par la minuterie de la charge intensive si le voyant DEL bleu est également allumé DEL ÉTAT DESCRIPTIONS COURBE DE CHARGE Clignotement rapide Reconditionnement clignotement lent charge à démarrage lent Allumé Charge intensive Bulk Masse 7 Vert Clignotant Allumé Un voyant clignotant correspond à la phase d égalisation un voya...

Page 16: ...est produit à la sortie La polarité est inversée à la connexion à la batterie Vérifier la connexion c c entre le chargeur et la batterie et s assurer qu elle ne cause pas de court circuit S assurer que les pinces crocodiles ne sont pas tombées de la batterie Vérifier que les pinces crocodiles cosses annulaires sont connectées selon la bonne polarité Pas de courant de charge Le voyant à DEL rouge d...

Reviews: