Operation Instruction of BS Series Solar Pumping Inverter
Operation Control
27
2. Conduct parameter setting for the motor
(a) Setting S00.01=0. Command code channel is keyboard manual mode instruction.
(b) Set water pump nameplate parameters: S02.01 motor rated power value; S02.02 motor rated
power value; S02.04 motor rated voltage value; S02.05 motor rated current value.
(c) After finishing parameter setting of water pump, set S00.01=1. The operation code channel is
altered as original automatic mode instruction.
See the following figure. The settings of nameplate parameters of water pump are listed as
follows (for example: 7.5KW inverter drives 5.5KW water pump):
Operation
Description
Display
Initial status:
non-historical data
display
↓
↓
↓
↓
↓
↓
Enter the main
parameter
modification interface
for long press 2s
Represent
:
S00 parameter group
Press OK key to enter
the branch menu
Represent
:
S00.00
Press UP key to view
the S00.01
Represent
:
S00.01
Press OK key to enter
the S00.01(the factory
set is 1)
Represent
:
1
Edited it to
0(controlled by
keyboard)
Represent
:
0
Press to save the
parameter value and
display the next code
number
Represent
:
S00.03