Operation Instruction of BS Series Solar Pumping Inverter
Operation Control
25
↓
↓
↓
↓
↓
Input voltage of
the inverter
Represent
:
542.3V
Output voltage of
the inverter
Represent
:
379V
Output current of
the inverter
Represent
:
11.1A
The relative value
of rated power
Represent
:
79.1%
Output frequency
of the inverter
Represent
:
50.00Hz
3.3 Work Mode
The inverter includes three work modes: keyboard manual mode, fully-automatic work mode,
GPRS work mode (optional). The default mode is fully-automatic work mode.
1: Keyboard manual work mode: menu S00. Setting S00.01=0. Press
key
to operate. Press
key for 2s, then the inverter stop working.
2: Fully-automatic work mode: menu S00. Setting S00.01=1. When sunlight is strong enough,
the inverter will automatically trace maximum power point. Under such mode, refer to inverter’s
operation parameter and DC switch to turn on/off the machine.
3:
GPRS work mode (optional): menu S00. Setting S00.01=2. Under such mode, bind