1
. PROGRAM THE CONTROLS
Using IQ Boiler Control Display
Viewing the operating Mode options
In operating mode the user may view (but not
change) boiler operating status, settings and
troubleshooting information. To view IQ Boiler
Control display information:
1
. Press and release the “
I
” key on the IQ
Boiler Control to change from one parameter
to the next. Each setting will alternately flash
between the relevant display code and its
corresponding value.
Operating Mode Options
StA
Status
bt
Boiler Temperature
SP
Operating Setpoint (Outdoor Reset)
HL
High Limit Setting
HdF
High Limit Differential
hr
Heat Request Status
FLA
Flame Current
rUn
Run Time Hours
CYC
Boiler Cycles
Err
Error (see Error Numbers)
Status Code Displayed in
STA
Mode
1
Standby:
Either TT Open or TT Closed and Boiler Temperature
within Setpoint and Differential with Circulator Running.
2
Waiting for Pressure Switch to Open
3
Waiting for Pressure Switch to Close
4
Prepurge
6
Spark
7
Flame Proving
8
Running
9
Postpurge
10 Retry/Recycle Delay
11 Pressure Switch Failed to Open
12 Pressure Switch Failed to Close
13 Soft Lockout
14 Hard Lockout
15 Waiting for Limit to Close
16 Flame Present Out of Sequence
17 Self Test
For example, when the “
I
” key is pressed on the
IQ Boiler Control until “
bt
” is displayed, it will then
flash a three digit number (such as “
180
”) followed
by either “
F
” (or “
C
”). This indicates that the boiler
water temperature is
180°F. Other operating
parameters display the information in a similar
fashion.
The IQ Boiler Control is located inside the boiler
front door, just above the IQ Option Panel (Figure
8-a).
ñ
1
8-b
ò
I
IQ Boiler Control
The IQ Boiler Control display, along with Up
ñ
,
Down
ò
, and “
I
” keys may be used to view boiler
operating status (Figure 8-b). Please note that
these keys look similar to the keys on the IQ
Option Panel but are in a different orientation, and
they perform different functions.
8-a
IQ Boiler Control
IQ option Panel
Summary of Contents for ESC
Page 6: ... Figure S 1 Minimum Clearances to Combustibles SPECIFICATIONS continued ...
Page 30: ...30 Internal Wiring Figure IW 1 Wiring Diagram ...
Page 31: ...31 Internal Wiring continued Figure IW 2 Wiring Diagram ...
Page 37: ...37 APPENDIX B1 INTENTIONALLY OMITTED ...
Page 50: ...50 Figure D 0 Piping Schematic Symbols APPENDIX D System Piping continued ...
Page 62: ...62 SERVICE RECORD DATE SERVICE PERFORMED ...