33
11) Verify Position of Hydraulic / Electrical
Lines
Check the location of all the hydraulic and electrical lines
to make sure they will not be damaged during the folding
and unfolding of the system.
12) Check System Lights For Proper Op-
eration
Verify that all the turn / stop / tail / reverse lights are
working properly. Replace any bulbs that are out.
There are two light circuits on the TMA. Verify both cir-
cuits are operational.
Raise the system to folded position and verify secondary
lights are working.
With the system unfolded, lights on the impact face will
be on and lights on the midframe will be off.
With the system folded, the lights on the midframe will
be on and the lights on the impact face will be off.
14) Final check
Check the tightness of all the fasteners. Check all steel cables
to verify that they are properly attached and tightened.
15) Ready to Use
The system is now ready for use.