Safe-Stop
®
180 TMA
30
Repair Instructions (cont’
Repair Instructions (cont’
Repair Instructions (cont’
Repair Instructions (cont’
Repair Instructions (cont’d.)
d.)
d.)
d.)
d.)
6) Install Cartridges
Remove one end of each alignment cable from the TMA
and set aside to clear the top side of each bay. Using a
forklift and sling, place Cartridge B in position and se-
cure it using the flat washers, lock washers and nuts pro-
vided. Torque the nuts to 120 ± 7 Nm [90 ± 5ft-lbs.] Re-
peat procedure for Cartridge A (see Figure 36).
Figure 36
CARTRIDGE B
CARTRIDGE A
7) Install the Top Release Cables across the
Arm Assemblies
Install the top release cable across the arm assemblies
(see Figure 35). Torque the nuts to 34 Nm (25 ft-lbs),
making sure that roughly an equal amount of threads
protrude from nuts on both ends of cable. Lock cable in
place using remaining fasteners as "jam" nuts.