15
11) Install Cartridges
Remove one end of each alignment cable from the TMA
and set aside to clear the top side of each bay. Using a
forklift and sling, place Cartridge B in position and se-
cure it using the flat washers, lock washers and nuts pro-
vided. Torque the nuts to 120 ± 7 Nm [90 ± 5ft-lbs.] Re-
peat procedure for Cartridge A (see Figure 19).
Figure 19
CARTRIDGE B
CARTRIDGE A
12) Install the Top Release Cables across
the Arm Assemblies
Install the top release cable across the arm assemblies
(see Figure 18). Torque the nuts to 34 Nm (25 ft-Ibf),
making sure that roughly an equal amount of threads
protrude from nuts on both ends of cable. Lock cable in
place using the remaining fasteners as "jam" nuts.
Summary of Contents for Safe-Stop 180 TMA 9181
Page 42: ...Safe Stop 180 TMA 42 ...
Page 43: ...43 ...
Page 46: ...Safe Stop 180 TMA 46 ...
Page 47: ...47 ...