ENERGIE
Page | 49
In the “1-Enable” configuration, it is not possible to change the operating modes of the heat
pump via the console.
After completing the aforementioned procedures, digital roads are available for use:
• REMOTE ON / OFF -
Turn equipment on or off remotely.
o Open contact, BC OFF;
o Closed contact, BC ON;
•
REMOTE HEAT / COOL -
Select Hot or Cold operating mode;
o Open contact, BC in Cooling mode;
o Closed contact, BC in Heating mode;
•
DHW ON / OFF -
Activate DHW function;
o Open contact, BC with inactive DHW function;
o Closed contact, BC with active DHW function;
•
HEAT / COOL ON / OFF -
Enable or disable BC operation in Hot
mode or in Cold mode:
o Open contact, BC on standby;
o Closed contact, BC active.
• 11/12 - Input for DHW tank temperature probe (probe provided in
the installation kit);
• 13/14 - Room thermostat (control by temperature probe);
• 17/18 - Output for 3-way DHW valve (DHW function activates output
voltage is 0V)
• 19/20 - Output for DHW circulating pump (DHW function activates
230Vac output voltage);
• 21/21 and 22/23 - command for support resistance (Imax = 1amp);