17.
Compensation VS ambient temperature
Compensation in heating mode
The temperature setpoint will be automatically adjusted according to the ambient
temperature.
When, R30 ≤ AT ≤ R29, or R29 ≤ AT ≤ 20, where AT = ambient temperature;
In these circumstances, the setpoint will be calculated according to the following
parameters:
Parameter
Descripition
Value
R02
Heating mode setpoint
user
R29
ON compensation in low outdoor
temperatures
-15
R30
OFF compensation at low outdoor
temperatures
-25
R42
Setpoint max. heating mode
55
R43
Setpoint max. heating mode at low outdoor
temperatures.
55
R44
Setpoint max. heating mode at high outdoor
temperatures.