22/28
Alarm
code
Problem
Charge
stop?
Cause
Action
A12
Deep discharge
.
No
This is a battery status message.
There's a deeply discharged battery
The default charge starts anyway
A13
Battery
disconnected
Temporary The battery is disconnected while
charging
Check that the charger is still
correctly connected to the battery.
If this is the case, check the cables
used to charge the battery and
replace them if necessary.
A14
Pump mistake
No
The air pump is malfunctioning
Please contact customer service
A16
Logic failure #2
Temporary There is a decrease in voltage
The charger restarts after 3 seconds.
If the problem persists, contact your
dealer.
A17
Flash checksum Yes
An error has occurred in the flash
memory
Turn the charger off, wait
30 seconds and turn the charger
back on.
If the problem persists, contact your
dealer.
A18
EEPROM ko
Yes
A problem has occurred in the
EEPROM communication
Turn the charger off, wait
30 seconds and turn the charger
back on.
If the problem persists, contact your
dealer.
Some alarms temporarily suspend the charge. The charge will restart after the alarm
conditions have disappeared.
Any alarm, with the exception of A02 and A13, is audible.
If none of these troubleshooting suggestions or solutions were helpful, please contact your local
dealer or the manufacturer.