background image

10

EG-PMS2-WLAN PROGRAMMABLE WLAN

SURGE PROTECTOR

All brands and logos are registered trademarks of their respective owners

2.2. Indicators

Main rocker switch

 Z (see Figure #1 above) is lit – this means that

EG-PMS2-WLAN is connected to the power supply and active

Power indicator

 (see Figure #1 above) is lit – this means that the

non-manageable sockets (marked with the sign

) are switched on

The  indicator

Socket  1  (2,3,4)

(see  Figure  #1  above)  is  lit –  this

means that this particular socket is switched on

The indicator

WLAN activity

(see Figure #2 above) blinks green –

this means that there is some WLAN activity taking place

The indicator

WLAN activity

(see Figure #2 above) lights green –

this means that EG-PMS2-WLAN is trying to connect to  wireless router

after power on.

3. Installation

It  is  strongly  recommended  to  avoid  damp  or  wet  places  for

installation.

EG-PMS2-WLAN  should  be  connected  to  the  European  AC  wall

socket of the standard DIN 49 440.

Summary of Contents for EG-PMS2-WLAN

Page 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF EG PMS2 WLAN PROGRAMMABLE SURGE PROTECTOR WITH WLAN INTERFACE...

Page 2: ...rface Programmier und steuerbare Steckdosenleiste mit WLAN Anschluss Programmeerbare WLAN stekkerdoos met overspanningsbeveiliging Bo tier command distance et programmable avec prise WLAN WiFi WLAN Do...

Page 3: ...edule and then disconnect EG PMS2 WLAN from WLAN and use it elsewhere The device can be used as an advanced standby killer With your free personal user account at EnerGenie com you can manage your EG...

Page 4: ...smartphone Switching on your coffee maker before setting off for home becomes a reality IP filter 64 bit password protected data encryption guarantees secure Internet access to EG PMS2 WLAN EG PMS2 W...

Page 5: ...um number of independent hardware schedule events 45 per socket Time setting accuracy in seconds Combine periodical and once events Timer accuracy not more than 2 seconds error per day in case that po...

Page 6: ...rk with WLAN router Any Internet enabled computer connected to the local area network Computer running Windows 2000 XP 7 8 is required for using the Power Manager software use of this software is not...

Page 7: ...trols of the EG P S2 WLAN Power indicator Non manageable socket Manageable socket 4 Manageable socket 3 Manageable socket 2 Manageable socket 1 Non manageable socket Indicator Socket 4 Indicator Socke...

Page 8: ...E WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners 2 1 Side panel 1 Reset Button A Master Switch Button B Power Indicator Figure 2 USB socket Antenna sock...

Page 9: ...GE PROTECTOR All brands and logos are registered trademarks of their respective owners Main rocker switch Z with power indicator and self recovering fuse Power Power cord On Reset after power consumpt...

Page 10: ...are switched on The indicator Socket 1 2 3 4 see Figure 1 above is lit this means that this particular socket is switched on The indicator WLAN activity see Figure 2 above blinks green this means tha...

Page 11: ...lled non manageable sockets in this manual If EG PMS2 WLAN is switched on then the red indicator POWER is lit In this case both non manageable sockets are now live and connected to the power supply Th...

Page 12: ...should keep the button pressed for more than 3 seconds To protect the connected devices from possible high current and short circuit EG PMS2 WLAN is equipped with the automatic circuit breaker NOTE If...

Page 13: ...ust download the latest software from www energenie com Follow instructions of the WLAN Config software see below 3 3 WLAN and local network configuration After software installation the WLAN Config u...

Page 14: ...espective owners corresponding fields in the WLAN config window then press the Configure button Figure 4 The configuration might take some time wait until it is completed If you see a string Connected...

Page 15: ...Figure 5 If your router has a DHCP server it will assign IP address to EG PMS2 WLAN automatically Alternatively you could input them manually using the checkbox Manual IP settings and then entering I...

Page 16: ...r for successful connection of EG PMS2 WLAN If you ever lost the IP address of EG PMS2 WLAN on your network you could use LAN Find utility See Figure 6 below to find it To do that select your wireless...

Page 17: ...17 EG PMS2 WLAN PROGRAMMABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 6...

Page 18: ...or other browser and input the IP address of EG PMS2 WLAN for example http 192 168 1 241 If you have used WLAN Config or Find EG PMS2 WLAN utilities to locate EG PMS2 WLAN then you will be taken to t...

Page 19: ...itch the sockets on and off manually The status of your sockets as well as the buttons to switch them on off are located at the top of the page NOTE the names of the sockets can be changed from the de...

Page 20: ...our login and password on this page and you are done Otherwise use the Registration button on the Login page to create a new account After your successful login regardless whether you created a new or...

Page 21: ...21 EG PMS2 WLAN PROGRAMMABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 8...

Page 22: ...erGenie com server If you eventually decide to change registration of your EG PMS2 WLAN and assign it to another account it will be possible via EnerGenie com website see section 5 below See section 5...

Page 23: ...egistered trademarks of their respective owners Figure 9 The socket shown on the Figure 9 is currently off it will be turned on again automatically on the 9th of July at 14 40 30 and on the same day a...

Page 24: ...ization Automatic timer synchronization is used if Use NTP for timer correction option is enabled see section 4 6 below NOTE If a certain socket has a switching fault e g it should be switched on but...

Page 25: ...RGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 10 Choose the date and time of the scheduled event If you wish the events to be executed periodically the...

Page 26: ...be reset and as result some schedule events would not be executed Besides all the sockets would lose their previous status they will be switched on In case of an empty battery just leave the device s...

Page 27: ...27 EG PMS2 WLAN PROGRAMMABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 11...

Page 28: ...28 EG PMS2 WLAN PROGRAMMABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners 4 5 LAN settings page Figure 12...

Page 29: ...you will need to know the MAC address of EG PMS2 WLAN It can be found on this page or on the bottom sticker of the device The MAC address is fixed and cannot be changed DNS server address is important...

Page 30: ...tility Authentication should correspond to the settings of your wireless router in AP mode It can be set to WEP64 WEP128 WPA TKIP WPA2 AES With WEP64 or WEP128 authentication modes you might additiona...

Page 31: ...SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners 4 6 Device settings page On the device settings page you can setup name password and internal time of EG PMS2...

Page 32: ...ebsite www pool ntp org NOTE for NTP time correction to work properly the device should have access to the Internet and have a proper DNS server setting see section 4 5 above Server name can be conven...

Page 33: ...ny other computer If another user tries to access the web server which is running an active session the error message will be shown on the login page Somebody with another IP has already logged in Try...

Page 34: ...nto your EnerGenie account just open the webpage www energenie com user in your Internet browser and enter your login and password in the login window see Figure 14 below Figure 14 Check Remember me c...

Page 35: ...TECTOR All brands and logos are registered trademarks of their respective owners 5 2 Device management page After a successful login you will see the list of your registered devices and their correspo...

Page 36: ...erver and the status of each socket Click your user name to change your account settings Click the device to change its name and or transfer it to another account Click the sockets to change their nam...

Page 37: ...r power management family products please visit www energenie com 6 1 Finding EG PMS2 WLAN To be able to manage preconfigured EG PMS2 WLANs please do the following Install Power Manager software on a...

Page 38: ...MMABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 16 The LAN devices window see Figure 17 below will appear click Add button there to add a n...

Page 39: ...vice window see figure 18 below please enter correct IP address port number 5000 by default and password 1 by default as configured on the Device settings page see section 4 6 above of the web server...

Page 40: ...Figure 18 Specified device should then appear with a green square next to it and Connected status in the LAN devices window see Figure 19 below NOTE Antivirus or firewall software may block connectio...

Page 41: ...lect it and click the Edit button or just double click on the LAN device To remove the WLAN device select it and click the Remove button You can select multiple WLAN devices using Ctrl and Shift keys...

Page 42: ...to access EG PMS2 WLAN from the PC which is not allowed to do so Change PC IP address or change IP filter list in EG PMS2 WLAN hardware settings see section 4 5 above EG PMS2 WLAN is not connected to...

Page 43: ...LAN by pressing the Reset button A on the side control panel see Figure 2 above or switch it off and then on again see Figure 1 above NOTE The Reset button A see Figure 2 above can sometimes help if E...

Page 44: ...g EG PMS2 WLAN After successful connection close LAN devices window You can now start managing EG PMS2 WLAN via the Power Manager interface Double click on the socket icon in the system tray or select...

Page 45: ...emarks of their respective owners Sockets should switch on and off green color means the socket is switched on red color means the socket is switched off when you double click on them Click the Settin...

Page 46: ...put the icon of the socket into the system tray You can choose the icon from drop down list box Such icon is a fast way to switch the device connected to the socket on off or check the device status...

Page 47: ...f their respective owners 7 Power Manager core features 7 1 Setting up the hardware schedule Using the Hardware schedule button available from the Settings window see section 6 2 above you can create...

Page 48: ...and click the Edit button or just double click on the entry see Figure 23 above The window Edit entry will appear To remove the record select it and click the Remove button see Figure 23 above You can...

Page 49: ...e Figure 23 above to save the hardware timer schedule changes In case of incorrect entries these will be highlighted and an error message will appear Click the Apply button again after correcting all...

Page 50: ...nal clock of the device would be reset and as result some schedule events would not be executed Besides all the sockets would lose their previous status they will be switched on Leave the device switc...

Page 51: ...LAN PROGRAMMABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 27 To add a new task click the Add button The Add task window will appear see Fig...

Page 52: ...ime and or Switch OFF time checkboxes and specify the time to switch the socked on and or off If you want the same event to be performed periodically check Perform task every checkbox and specify the...

Page 53: ...elect it see Figure 27 above and click the Edit button or just double click on the task The Edit task window will appear see Figure 29 below Figure 29 To remove the task select it and click the Remove...

Page 54: ...tting up application events Using the Application events window you can specify the socket events when a certain application is launched or closed down You can also associate switching the sockets off...

Page 55: ...MABLE WLAN SURGE PROTECTOR All brands and logos are registered trademarks of their respective owners Figure 30 To add a new program event click the Add app button The Add program event dialog will app...

Page 56: ...it using the Browse button or typing it manually in the Title and Path name fields If you use the Browse button you can also select a shortcut to the application In this case the application title an...

Page 57: ...d application is opened The On exit event will take place when the last window of the application is closed HINT Your device is an advanced standby killer Using this feature you can for example switch...

Page 58: ...the specified folder The On removal event will take place when the last file matching the specified file name mask is removed from the specified folder HINT Your device is an advanced standby killer...

Page 59: ...ctive owners Figure 33 To remove the event select it and click the Remove button see Figure 30 above You can select multiple events using Ctrl and Shift keys You can also remove all events by clicking...

Page 60: ...name Examples C Program Files Energenie Power Manager pm exe on My EnerGenie Socket1 E Utils PM3 pm exe off My EnerGenie Table lamp Execute pm exe with info key pm exe info to get the complete inform...

Page 61: ...aced by a certain socket number TRUE when voltage presence on the socket is detected FALSE when there is no voltage on the socket Example NOTE Each use of this command line option totally overrides th...

Page 62: ...the power supply and the rocker switch is switched on The status of EG PMS2 WLAN in Power Manager does not become Connected Maybe network settings problem Try to ping the device see section 6 1 above...

Page 63: ...mplies with the essential requirements of the laws of member states concerning R TTE 1999 5 EC The CE declaration can be found under www gembird eu Dieses Produkt wurde getestet und stimmt mit den gru...

Page 64: ...d Elektronikger ten Richtlijnen m b t afvalverwerking Batterijen en accu s dienen als klein chemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten zie www afvalgids nl U dient ervoor t...

Page 65: ...note The credit note amount will always be calculated on the basis of the current market value of the defective products Das Kaufdatum und der Ger tetyp sind durch eine maschinell erstellte Kaufquitt...

Page 66: ...nservez le re u d achat pendant toute la dur e de la garantie car elle est n cessaire pour toute r clamation Au cours de la p riode de garantie tous les d fauts doivent tre remplac aux frais du fabric...

Page 67: ...___ ____ ___________________ 20____ _________________________________ ________________________________________________ _____________ _____________ 1 2 3 4 ____________________ ________________________...